Table 1 - TWA Unit Electrical Data
Model
Electrical
Number
Characteristics
TWA090A3
208-230/60/3
TWA090A4
460/60/3
TWA090AW
575/60/3
TWA075AD
380-415/50/3
TWA120A3
208-230/60/3
TWA120A4
460/60/3
TWA120AW
575/60/3
TWA100AD
380-415/50/3
TWA180B3
208-230/60/3
TWA180B4
460/60/3
TWA180BW
575/60/3
TWA155BD
380-415/50/3
TWA240B3
208-230/60/3
TWA240B4
460/60/3
TWA240BW
575/60/3
TWA200BD
380-415/50/3
8

Electrical Data

Basic Unit Characteristics
Allowable
Minimum Maximum
Voltage
Circuit
Range
Ampacity
187-254
34.5
414-506
18.1
518-632
14.5
380-415
12.6
187-254
48.1
414-506
23.3
518-632
18.8
380-415
22.5
187-254
62.7
414-506
32.9
518-632
26.3
380-415
28.4
187-254
87.8
414-506
42.5
518-632
34.2
380-415
41.0
Compressor Motor
Fuse
Amps
Size
Qty.
RLA
LRA
50
1
25.1
182.0
25
1
13.2
94.9
20
1
10.6
70.0
20
1
8.8
90.0
70
1
33.7
278.0
35
1
16.5
124.0
25
1
13.4
92.0
35
1
15.8
124.0
80
2
25.1
182.0
45
2
13.2
94.9
35
2
10.6
70.0
35
2
11.2
94.9
100
2
33.7
278.0
50
2
16.5
120.0
45
2
13.4
92.0
50
2
15.8
124.0
Outdoor Fan Motor
Amps
Qty. HP
FLA
LRA
1
1/2
3.1
8.1
1
1/2
1.6
3.7
1
1/2
1.2
3.0
1
1/2
1.6
3.7
1
1
6.0
17.5
1
1
2.7
7.0
1
1
2.0
5.7
1
1
2.7
7.0
2
1/2
3.1
8.1
2
1/2
1.6
3.7
2
1/2
1.2
3.0
2
1/2
1.6
3.7
2
1
6.0
17.5
2
1
2.7
7.0
2
1
2.0
5.7
2
1
2.7
7.0