Loading and Saving Presets with
SysEx
Command|8 supports SysEx to store and recall
presets into and out of Pro Tools or any compat-
ible device. SysEx provides a standard and reli-
able way to quickly archive, and later retrieve
entire sets of Command|8 presets.
To save the current presets to SysEx:
If not already opened and displayed, press F3
1
PRE MIDI Recall to select the desired preset.
If recording SysEx into Pro Tools MIDI track,
2
do the following:
• Enable Wait for Note
• Create a new MIDI track (if necessary) and
configure input and output as described in
the Pro Tools Reference Guide.
• Configure the MIDI Input Filter dialog to
enable SysEx recording.
• Record enable the MIDI track, and arm the
Pro Tools Transport for recording (be sure
you enabled Wait for Note so that record-
ing will not begin until the SysEx transfer
starts).
Press the channel 8 Select switch (Save).
3
Press the channel 2 Select switch to cycle
4
through available destinations
• To save to a SysEx destination connected
through USB (such as Pro Tools), choose
MIDI/USB.
• To save to a SysEx destination connect
through 5-pin DIN MIDI connections,
choose MIDI/DIN.
When the desired destination is chosen, press
5
the channel 7 Select switch (OK).
50
Command|8 Guide
When Command|8 prompts you to save the
6
currently displayed preset to flash memory, do
one of the following:
• To confirm and save, press the channel 7
Select switch (Okay). This replaces the pre-
set previously stored in flash memory.
– or –
• To cancel without saving, press the chan-
nel 6 Select switch (Cancel).
If you OK the SysEx dump, the LCD displays a
status message until the transfer is completed,
after which it returns to the previous preset
view.
To load (recall) presets from SysEx:
Make sure the device from which you will be
1
loading SysEx data is connected properly to
Command|8 (either through a USB MIDI or a 5-
pin DIN MIDI connection).
If loading from a Pro Tools track, cue Pro Tools
2
to the appropriate location before the SysEx
data.
Press F3 PRE MIDI Recall. Scroll to the Com-
3
mand|8 preset where you want to load (over-
write) the incoming preset being recalled.
Press the channel 7 Select switch (Recall).
4
Press the channel 2 Select switch to choose ei-
5
ther USB MIDI or MIDI/DIN to recall from. If
loading from a Pro Tools MIDI track, choose
USB MIDI.
Press the channel 7 Select switch (Okay).
6
Command|8 waits for SysEx data to begin arriv-
ing.
Begin the SysEx source device (if using
7
Pro Tools, begin playback). Command|8 dis-
plays a status message while loading.