Temperature Management Commands

Viewing the Status:
device-name#show temperature
CPU Temperature = 28C / 82F
device-name#show temperature high-limit
CPU Temperature high limit = 20C / 68F
Configuring Temperature Management Parameters:
device-name#configure terminal
device-name(config)#monitor temperature
device-name(config monitor temperature C)#limit
NUMBER
device-name(config monitor temperature C)#limit 70
Viewing the Temperature Setting from a Running Configuration:
device-name#show running-config
Building the configuration ...
! Current Configuration:
!
! Version 2.0
!
password a1FhfHKwXHFlU
ip address 10.4.1.5 255.255.0.0
!
! Switch Monitoring configuration:
!
monitor temperature
enable
limit 70
!
Restoring the Default Value:
device-name#configure terminal
device-name(config)#monitor temperature
device-name(config monitor temperature C)#default