USER GUIDE K P - 1 6 0 P G 2 K e y p a d U s e r ' s G u i d e www.visonic.com...
Page 2
PANIC: Press both keys disabled DISARM simultaneously for 2 seconds LED (green and red) ARM HOME / QUICK ARM HOME AUX / Enroll KP-160 PG2 / Back to factory / Cancel ARM AWAY / QUICK ARM AWAY current operation LATCHKEY...
(see keys marked "7" in the "Icon and Key Indications" Figure). The KP-160 PG2 can be wall-mounted using the supplied bracket or be used as a portable unit. For compliance with various international standards, the KP-160 PG2 is equipped with two tamper switches that can be defined to detect when the cover of the battery compartment is removed or when the unit is removed from its mounting bracket.
Figure 3 - Battery Cover Mounting (part b) A. Tamper B. DC Power Connection 2.3 Wall Mounting Options The KP-160 PG2 unit mounting options are illustrated in the following drawings. Wall Mounting Figure 4a – Wall Mounting 1. Drill 3 mounting holes 3.
Page 7
Figure 4b – Wall Mounting with External Electrical Connector 1. Secure bracket with 2 screws as shown in the two drawings above. 2. Attach the unit to the bracket. 3. Secure the unit with the screw D-303169 KP-160 PG2 User’s Guide...
See section 2.5 means scroll and select Note: If the KP-160 PG2 is already enrolled, you can configure the KP-160 PG2 parameters via the “Modify Devices” option – see Step 2. 2.5 Configuring the KP-160 PG2 Parameters K07.DEV SETTINGS...
Page 9
1) When the "SCREEN SAVER" menu on the PowerMaster control panel is configured as "refresh by key", touching the right side of the screen on the KP-160 PG2 device will return the device to normal display (refer to the PowerMaster Installer Guide, section 3.5.6).
Note: For UL Listed product, set to “NOT Connected”. 2.6 Enrolling Proximity Tags You can enroll proximity tags in the PowerMaster panel either via the KP-160 PG2 touch screen keyprox, as described below, or through the PowerMaster control panel, as described in the corresponding section of the control panel's User or Installer Guide.
INSTANT is available only if supported in the PowerMaster control panel (refer to the PowerMaster Installer Guide). For LATCHKEY activation, press the LATCHKEY key within maximum 8 seconds timeout period after completing the previous step. D-303169 KP-160 PG2 User’s Guide...
Response Notes Emergency See section When pressing the Fire or Emergency alarm 3.3. icons, the KP-160 PG2 starts beeping. ( 2 sec.) After pressing the button for approx. 2 seconds, the KP-160 PG2 sends the Fire alarm See section command.
Page 13
System is READY but one or more zones are bypassed. No indication System is READY and all zones are secured. Bypassed ( ) or Open ( ) Zone number Selected PGM or X-10 unit number. D-303169 KP-160 PG2 User’s Guide...
Page 14
Indicates that the KP-160 PG2 device's battery is low and must be replaced (see section 2.1). [1] The key indication is displayed after the first red LED blinks indicating the status request.
Page 15
When "00" appears on the Zone # display, this indicates a NOT READY state in the alarm system that is not related to any detector, for example, "tamper open" in a keypad or control panel. If all zones are READY and "not bypassed", the button is disabled. D-303169 KP-160 PG2 User’s Guide...
(marked "4" in the "Icon and Key Indications" Figure) followed by the key. Notes: 1. Zone bypassing on the KP-160 PG2 unit can be operated only if Bypass was enabled via the control panel (see PowerMaster Installer Guide, section 3.5.2 "Configuring Arming/Disarming and Exit/Entry Procedures").
Enrollment: Long key press (more than 5 sec.) until green LED lights and then release key. Back to Factory: Long key press (more than 7 sec.) to reset the KP-160 PG2 device to factory default settings. Cancels current operation: Short key press Volume control Changes the volume level upon each key press.
Page 18
– Connect the device to an outlet on a circuit different from the one which supplies power to the receiver. – Consult the dealer or an experienced radio/TV technician. Changes or modifications not expressly approved by Visonic Ltd. could void the user's authority to operate the equipment.
Notes Emergency alarm See section 3.2. Shortly after pressing the Emergency or Fire icon, the KP-160 (≈ 2 sec.) PG2 emits beeps until the KP-160 PG2 sends the command. Fire alarm See section 3.2. (≈ 2 sec.) Panic alarm See section 3.2.
Page 20
Wireless Detector with Curtain-type Internal Siren Detector Wireless Wireless PIR/ PIR Camera Pet-immune Detector Detector Wireless Wireless Indoor Outdoor Siren Siren Proximity GSM/GPRS Tags Communicator PowerG Technology for life Contact Visonic for further information: Email: info@visonic.com Tel: +972 3 6456789...