stephen salisbury
January 27, 2025

the display is very feint and the reading says communicating. the keypad was fitted around two years ago and worked till recently.

1 comments:
Mr. Anderson
May 14, 2025

A faint display and a "communicating" message on a Visonic KP-250 keypad could be caused by the keypad attempting to send a command to the control panel. During this process, the keypad's LED blinks red to indicate communication. If the operation is successful, the green LED lights momentarily and a sound is heard. If the operation fails, the red LED stays on and a different sound plays. A faint display may also suggest low battery power or weak signal strength.

This answer is automatically generated

Summary of Contents for Visonic KP-250

  • Page 1 USER GUIDE K P - 2 5 0 P G 2 K e y p a d U s e r ' s G u i d e ALARM INTERNATIONAL SYSTEMS WWW.AIS-SECURITY.BE...
  • Page 2 Arming and Disarming the System Icon/Key Indications Arming Indication ARM AWAY ARM HOME DISARM EXIT DELAY The icons appear consecutively Programming Functionality String Editor Functionalityl ‘ ‘, ‘0’ ‘.’, ‘,’, ‘1’ ‘a’, ‘A’, ‘b’, ‘B’, ‘c’, ‘C’, ‘2’ ‘d’, ‘D’, ‘e’, ‘E’, ‘f’, ‘F’, ‘3’ ‘g’, ‘G’, ‘h’, ‘H’, ‘i’, ‘I’, ‘4’...
  • Page 3: Table Of Contents

    B.3 Recalling the Zone Bypass Scheme ......................25 B.4 Programming User Codes ..........................26 B.5 Programming the Duress Code ........................28 B.6 Add / Delete Proximity Tags ........................... 29 B.7 Add / Delete Keyfob Transmitters ........................31 D-304269 KP-250 PG2 User’s Guide...
  • Page 4 B2. Arming / Disarming the System ........................60 B3. The Show Function ............................61 B4. Siren ................................61 B5. Partition Status display ........................... 61 B6. Common Areas .............................. 62 APPENDIX C: Glossary ..............................63 APPENDIX D: Compliance with Standards ........................66 D-304269 KP-250 PG2 User’s Guide...
  • Page 5: Introduction

    Introduction KP-250 PG2 is a 2-way wireless PowerG keypad display device for use with the PowerMaster-10 G2 / PowerMaster-30 G2 / PowerMaster-33 G2 control panel (version 18 and higher). Up to 10 KP-250 PG2 keypads can be enrolled in the PowerMaster system.
  • Page 6: Additional System Features

    Security codes are used mainly to arm and disarm the system or to access information that is restricted only to authorized users (see Chapter 6, section B.4, Programming User Codes). In option 2, the KP-250 PG2 keypad will not operate (respond) if the KP-250 PG2 is assigned to two or more partitions.
  • Page 7: Speech & Sound Cont. Push-Buttons

    Note: The system will maintain the “MUTE OFF” state until subsequent selection of “MUTE ON’. Recording a Message You can record a verbal message on the PowerMaster control panel, by the KP-250 PG2, for other users of the alarm system. Face the panel, press on the KP-250 PG2 keypad and keep it pressed.
  • Page 8: Message Playback

    Message playback is performed by the control panel. To listen to a message left by another user of the system: Click on the KP-250 PG2 keypad and listen. PLAY will be displayed and the message will be played back over the PowerMaster loudspeaker or external voice box. When the playback ends, the display will revert to the normal status- displaying mode.
  • Page 9: Arming And Disarming The System

    To review the open zones click on the KP-250 PG2 keypad. The details and location of the first open zone detector (usually an open door or window sensor) will be displayed. To fix the open zone, locate the sensor and secure it (close the door or window) –...
  • Page 10 Move to interior zone (ARM HOME) AWAY/HOME ARM indicator on both the KP-250 PG2 keypad and PowerMaster panel lights steadily during the armed state. Disarming and Stopping Alarm Enter the protected premises via a delayed zone. Upon detecting your entrance, the system will start sounding the entry delay beeps alerting you to disarm the system before the entry delay ends.
  • Page 11: Special Arming & Disarming Options

    3. Arming and Disarming the System Special Arming & Disarming Options In addition to basic arming, KP-250 PG2 provides you with several advanced arming and disarming options: Switching from ‘HOME’ to ‘AWAY’ You do not have to disarm the system - just press .
  • Page 12 (to mute the buzzer) AWAY Vacate the premises ARM indicator on both the KP-250 PG2 keypad and PowerMaster panel lights during the armed state. Remember: Forced arming compromises security!! Forced arming “HOME” is performed in a similar manner, as follows:...
  • Page 13: Initiating Alarms

    (Exit delay) AWAY Note: Latchkey must be enabled by your installer. ARM indicator on both the KP-250 PG2 keypad and PowerMaster panel lights during the armed state. Initiating Alarms Following are various methods that may be used for initiating alarms.
  • Page 14 Disable / enable the chime zones by alternate clicking of the key, as shown below: PRESS RESULTING DISPLAY CHIME ON CHIME OFF ↓ HH:MM READY CHIME indicator lights steadily on the KP-250 PG2 keypad, when “chime on” is selected. D-304269 KP-250 PG2 User’s Guide...
  • Page 15 3. Arming and Disarming the System Adjusting the Volume of the Keypad Beeps The following diagrams show how to increase or decrease the loudness by clicking the <1> or<4> key on the KP-250 PG2 keypad (assuming that the volume was at minimum/maximum to begin with).
  • Page 16: System Status And Indications

    Note: The icons and numbers shown on the above keypad drawing are for illustrative purposes only. When executing a command, the KP-250 PG2 keypad's LED blinks red once to indicate transmission of the command to the control panel. If the operation is successfully completed, the green LED lights momentarily and a "happy tune"...
  • Page 17: General Indications

    PGM control System Trouble Event log / enroll button Escape Instant Previous Partition selection Info. / OK Dialer to call telephone numbers (for Next future use) AC failure Discard / abort Not supported in this version D-304269 KP-250 PG2 User’s Guide...
  • Page 18: Alarm Indication Siren

    ON - ON - ON - ON - pause - ON - ON - ON - ON - pause..Test* –– (both external siren and internal sounder) ON for 2 seconds (once) * Not included in all models D-304269 KP-250 PG2 User’s Guide...
  • Page 19: Reviewing Troubles And Alarm Memory

    Alarm & Tamper Memory Indication The KP-250 PG2 retains in its memory alarm and “tamper” events that occurred during the last arming period. Note: Alarm events are memorized only after the “abort period”. This means that if you disarm the system immediately - before the abort period expires - there will be no memory indication A.
  • Page 20: Gsm/Gprs Status Indications

    GSM/GPRS Status Indications After all trouble messages have been reviewed and if a SIM card is installed in the panel, the KP-250 PG2 displays the GSM signal strength indication, as follows: "GSM RSSI STRONG" / "GSM RSSI GOOD" / "GSM RSSI POOR".
  • Page 21: Trouble Indications

    RSSI LOW There is no power to the siren SIREN AC FAILURE The sensor has an open tamper TAMPER FAILURE The sensor reports trouble TROUBLE Detector alarms when is Soak Test mode SOAK TEST FAIL D-304269 KP-250 PG2 User’s Guide...
  • Page 22: System Configuration

    This chapter explains the user programming features of your PowerMaster system using the KP-250 PG2 keypad. To access the User Settings menus, a KP-250 PG2 keypad must first be enrolled in the system. For instructions on how to enroll the KP-250 PG2 Keypad, refer to the KP-250 PG2 Installer’s Guide, section 11.4.
  • Page 23 TIME & FORMAT and programming procedure see section B.8. DATE & FORMAT Use to set the calendar date to show the correct date and date format. For further details and programming procedure see section B.9. D-304269 KP-250 PG2 User’s Guide...
  • Page 24: Returning To The Previous Step Or Exiting The User Settings Menu

    User Settings menu. 1. To Move One Level Up To move one level up during the setting process, click once or more. Each click will take you one level up or to the previous setting step. D-304269 KP-250 PG2 User’s Guide...
  • Page 25: Buttons Used For Navigation & Setting

    B.3. Fire zones cannot be bypassed. Carefully read the section titled "Additional Information" according to the indicated references etc – see table at end of section B.3. REMEMBER – ZONE BYPASSING COMPROMISES SECURITY! D-304269 KP-250 PG2 User’s Guide...
  • Page 26 The display now reads [<OFF> TO CLEAR]. To clear the bypassed zone, press the button. Z04:READY A "Happy Tune" ☺ sounds and the updated zone status is now displayed, i.e. Z04: READY Z04: NOT READY ] or [ D-304269 KP-250 PG2 User’s Guide...
  • Page 27: Reviewing The Zone Bypass Scheme

    If the zone you selected is "not bypassed", the display prompts you to press [ ]. However, <OFF> TO CLEAR if the zone you selected is already "bypassed", the display prompts you to press [ D-304269 KP-250 PG2 User’s Guide...
  • Page 28: Programming User Codes

    (PowerMaster-10 G2) / 32 (PowerMaster-30 G2 / PowerMaster-33 G2) multi-function portable keyfob transmitters that will allow you and the other users to easily arm, disarm and control the system without accessing the KP-250 PG2 or panel, including from outside the premises (see section B.7 Add / Delete Keyfob Transmitters). The Duress Code enables you to disarm the system using a special code that sends a silent alarm to the monitoring station.
  • Page 29 User 06: 0000 3, 4 for example, “1234”, using the numerical keypad. When done, press User 06: 1234 ☺ ☺ 5, 6 Return to step 3 A "Happy Tune" sounds. The display confirms the saved code. D-304269 KP-250 PG2 User’s Guide...
  • Page 30: Programming The Duress Code

    ♦ Here you program the duress code. Carefully read the section titled "Additional Information" according to the indicated references etc – see table at end of this section. ∗ Refers to when PARTITIONING is enabled. D-304269 KP-250 PG2 User’s Guide...
  • Page 31: Add / Delete Proximity Tags

    The display will read [ADD NEW TAG]. ADD NEW To begin the process of enrolling a new proximity tag press Present the proximity tag to the KP-250 PG2 within the timeout period. ENROLL NOW or ENTR ID:xxx-xxxx If enrollment was successfully completed, a "Happy Tune"...
  • Page 32 When the tag you wish to delete appears on the display, press <DEL> to delete The display now reads [<DEL> to delete]. To delete the tag press the button. ∗ Refers to when PARTITIONING is enabled. D-304269 KP-250 PG2 User’s Guide...
  • Page 33: Add / Delete Keyfob Transmitters

    Partition Option (For information about Partition option - see APPENDIX B). If the Partition option is enabled in the KP-250 PG2, each of the 8 (PowerMaster-10 G2) / 32 (PowerMaster-30 G2 / PowerMaster-33 G2) keyfobs can be authorized by the Master User to arm and disarm any combination, or all 3 partitions, irrespective of the authorization of its corresponding user code.
  • Page 34 The display reads [ ] or [ ] if the keyfob was ☺ Return to step 2 ☺ enrolled manually by entering the ID number, a "Happy Tune" sounds and the display will then change to [ F01:Keyfob D-304269 KP-250 PG2 User’s Guide...
  • Page 35 When the keyfob you wish to delete appears on the display, press ID No. 300-5799 The display now reads [<DEL> to Delete]. <DEL> to Delete To delete the keyfob press the button. ∗ Refers to when PARTITIONING is enabled. D-304269 KP-250 PG2 User’s Guide...
  • Page 36: Setting The Time & Time Format

    You can now enroll another keyfob. You can also select another option in the User Settings menu (see section A.1 and section A.2), or quit programming (see section A.3). If the keyfob was previously enrolled in the system, the KP-250 PG2 display indicates this together with the ALREADY ENROLLED keyfob's ID number, for example, "...
  • Page 37 The time saved is displayed without the cursor, for example, " " followed by the selected time format. You can now select another option in the User Settings menu (see section A.1 and section A.2), or quit programming (see section A.3). D-304269 KP-250 PG2 User’s Guide...
  • Page 38: Setting The Date & Date Format

    You can now select another option in the User Settings menu (see section A.1 and section A.2), or quit programming (see section A.3). This setting can be performed only after completing steps 1 – 3 of section B.9A. D-304269 KP-250 PG2 User’s Guide...
  • Page 39: Enabling / Disabling Auto-Arming

    When you are satisfied with the setting, press to confirm. A "Happy Tune" ☺ sounds. The display confirms the saved time, then returns to AUTO-ARM TIME 5, 6 the User Settings menu, step 1. 08:30 ☺ Return to step 1 D-304269 KP-250 PG2 User’s Guide...
  • Page 40: Programming Private Phone And Sms Reporting

    Enter the [USER SETTINGS] menu and select the [PRIVATE REPORT] option PRIVATE REPORT and press VOICE REPORT The display will read [VOICE REPORT]. To enter this option press ∗ Refers to system that is connected to the Voice Box D-304269 KP-250 PG2 User’s Guide...
  • Page 41 C. To Program the Number of Redial Attempts Click the button until the display reads [REDIAL ATTEMPTS] and Private tel#2 press REDIAL ATTEMPTS 3 alarms The display shows the currently selected option. REDIAL ATTEMPTS 3 alarms D-304269 KP-250 PG2 User’s Guide...
  • Page 42 The display shows the currently selected option. TEL.ACKNOWLEDGE by single ack Click the button until the display reads the desired acknowledge ∗ Refers to system that is connected to the Voice Box D-304269 KP-250 PG2 User’s Guide...
  • Page 43 6, 7 SMS phone number, for example, “5080168593”, using the numerical keypad. When done, press to confirm. ☺ 8, 12 SMS tel#2 A "Happy Tune" sounds and the display confirms the SMS phone number. 5080168593 D-304269 KP-250 PG2 User’s Guide...
  • Page 44 You can select between: " "; " "; " "; " ". You can select between: enable " " – enables 2-way voice communication with private telephones. disable " " - disables 2-way voice communication with private telephones. D-304269 KP-250 PG2 User’s Guide...
  • Page 45: Enabling / Disabling The Squawk Option

    You can now enable (ON) or disable (OFF) the Squawk option using the button. symbol now appears next to the new selected option. You can now select another option in the User Settings menu (see section A.1 and section A.2), or quit programming (see section A.3). D-304269 KP-250 PG2 User’s Guide...
  • Page 46: Programming The Scheduler

    The "start time" screen is shown on the display. − − − − − − − − :− − − − − − − − To set the start time of the selected operation, press the button. D-304269 KP-250 PG2 User’s Guide...
  • Page 47 For detailed explanation of how to set the time - refer to Section B.8B. To end this session and return to the previous "operation" menu, press the button. To select other menu options or to quit programming, follow the instructions in sections A.2 and A.3. D-304269 KP-250 PG2 User’s Guide...
  • Page 48: Enabling / Disabling Voice Option

    Enter the [USER SETTINGS] menu, select the [VOICE OPTION] option and press VOICE OPTION enable The display shows the currently selected setting. VOICE OPTION enable ∗ Refers to system that is connected to the Voice Box D-304269 KP-250 PG2 User’s Guide...
  • Page 49: Adjusting The Volume Of The Control Panel Or External Box

    KP-250 PG2 keypad. B.16 Adjusting the Volume of the Control Panel or External Box∗ The KP-250 PG2 allows you to adjust the volume of the PowerMaster control panel or an external voice box. ♦ Here you can increase or decrease the loudness.
  • Page 50: Serial Number

    PANEL ID 100005 Displays the GSM image transfer software version. PYTHON VERSION FFFFFFFFF Displays the control panel default version. EE CAT & SN J-702271 K18.022 Displays the KP-250 PG2 keypad software version. KP250 SW VER 01.00.09 D-304269 KP-250 PG2 User’s Guide...
  • Page 51 6. System Configuration Displays the KP-250 PG2 keypad catalog number. KP250 cat.number 70245100 Displays the software upgrade communicator version RSU VERSION 7S702415 K01.034 Displays the software upgrade boot/programmer version BOOT VERSION 7S702412 K01.022 Return to step 2 Additional Information (section B.17) For detailed instructions on how to select the Setting Options –...
  • Page 52: Advanced Features

    A “Happy Tune” indicates successful saving of a new option. PRESS RESULTING DISPLAY BY TIMER ON (If this is the default) BY TIMER OFF If not satisfied - press If satisfied - BY TIMER OFF press BY TIMER OFF D-304269 KP-250 PG2 User’s Guide...
  • Page 53 7. Advanced Features PRESS RESULTING DISPLAY BY SENSOR ON (If this is the default) BY SENSOR OFF If not satisfied - Press BY SENSOR OFF If satisfied - BY SENSOR OFF HH:MM READY D-304269 KP-250 PG2 User’s Guide...
  • Page 54: Periodic Test By User Code

    Siren Test: Each siren of the system is automatically activated for 3 seconds (outdoor sirens with low volume). In addition, the system tests the siren of enrolled smoke sensors. Temperature Sensor Test: When Temperature Sensors are enrolled in the system, the KP-250 PG2 displays the temperature of each zone in Celsius or Fahrenheit.
  • Page 55 To display the temperature of zones on the KP-250 PG2, press Z01 +19.5° ° ° ° C The KP-250 PG2 reads the temperature of each zone. The display alternates Z01:Temp. Sensor between the temperature, the sensor number and the sensor location.
  • Page 56 If the INSTALLER CODE is used to enter the Periodic Test instead of the USER CODE, the devices LED will also provide the link quality indication – refer to Chapter 4 of the KP-250 PG2 Installer’s Guide, Periodic Test by Installer Code.
  • Page 57: Periodic Test Per Partition

    DEVICE TESTS END After a device has been activated, the control panel reads [Zxx IS ACTIVATED] and the "N" indicator drops one count. After all devices have been tested, the control panel reads [DEVICE TESTS END]. D-304269 KP-250 PG2 User’s Guide...
  • Page 58 Periodic test per partition will be interrupted (the panel returns to selected partition display) upon occurrence of one of the following: 1) Disarm event by keyfob, keypad or pendant assigned to a selected partition; 2) PANIC, FIRE or EMERGENCY event. D-304269 KP-250 PG2 User’s Guide...
  • Page 59: Maintenance

    Access to the event log is provided by clicking the button and then keying your master user code. To get an overall view of using the log, refer to the procedure below. D-304269 KP-250 PG2 User’s Guide...
  • Page 60: Exiting The Event Log

    When the KP-250 PG2 display reads [PRESENT TAG OR ENTER CODE: CODE enter the current master user code or present your tag. The "Happy Tune" will sound and the display will read [KP-250 LIST OF KP-250 EVENTS]. (see Important Note!)
  • Page 61: Appendix A: Specifications

    Average relative humidity of approx. 75% non -condensing. For 30 days per year, relative humidity may vary from 85% to 95% non-condensing. 150x100x20mm (5-7/8 x 3-7/8 x 13/16 in) Dimensions (WxLxD) Weight (including battery and bracket) 379 g (13 oz). Wall-mounted or desktop Mounting Color White D-304269 KP-250 PG2 User’s Guide...
  • Page 62: Appendix B: Partitioning

    Partitioning Partitioning The KP-250 PG2 includes an optional partition feature. Partitioning is available only if your installer has enabled the feature. Once partitioning is enabled Partitioning menus are added to the system which can be viewed on the LCD display.
  • Page 63: B3. The Show Function

    B5. Partition Status display Partitions status is indicated in the following manner: P1:X P2:X P3:X Each X value indicates a different partition state, as follows: Ready Not ready Away Home Exit delay Entry delay Not used D-304269 KP-250 PG2 User’s Guide...
  • Page 64: B6. Common Areas

    • Acts as a Delay type when at least one of the assigned partitions is armed HOME. • Will be ignored when at least one of the assigned partitions is disarmed. Emergency; Fire; Flood; Gas; • Always armed. Temperature; 24-hour silent; 24-hour audible; Non-alarm D-304269 KP-250 PG2 User’s Guide...
  • Page 65: Appendix C: Glossary

    Disturbed Zone: A zone in a state of alarm (this may be caused by an open window or door or by motion in the field of view of a motion detector). A disturbed zone is considered “not secured”. D-304269 KP-250 PG2 User’s Guide...
  • Page 66 To disarm the system without causing an alarm, use your control keypad (which is normally accessible without disturbing a perimeter zone) or use a keyfob transmitter. It's me: The KP-250 PG2 system includes a powerful device locator that helps you to identify the actual device displayed on the LCD, as follows: While the LCD displays a zone (device), the LED on the respective device flashes indicating "it's me".
  • Page 67 Status: AC fail, low battery, trouble, system state etc. User Codes: The KP-250 PG2 is designed to obey your commands, provided that they are preceded by a valid security access code. Unauthorized people do not know this code, so any attempt on their part to disarm or defeat the system is bound to fail.
  • Page 68: Appendix D: Compliance With Standards

    – Connect the device to an outlet on a circuit different from the one which supplies power to the receiver. – Consult the dealer or an experienced radio/TV technician. Changes or modifications not expressly approved by Visonic Ltd. could void the user's authority to operate the equipment. W.E.E.E. Product Recycling Declaration For information regarding the recycling of this product you must contact the company from which you orignially purchased it.
  • Page 69 WARRANTY Visonic Limited (the “Manufacturer") warrants this product only (the However, if the Manufacturer is held liable, whether directly or "Product") to the original purchaser only (the “Purchaser”) against indirectly, for any loss or damage arising under this limited warranty,...
  • Page 70 KP-250 PG2 User’s Guide D-304269 (Rev 2, 12/14) D-304269 KP-250 PG2 User’s Guide...
  • Page 71 Quick Reference Guide Volume up Dialer to call telephone Sabbath mode Record a message numbers (for future use) Instructs the user to present PGM on EMERGENCY the proximity tag (at the Volume down FIRE ALARM position of this indication) Play a message AC failure AC ON PGM off...
  • Page 72 Additional PowerG Products for Your Security and Safety Needs: Wireless Fire Detector Wireless Curtain-type with Internal Siren Detector Wireless PIR/Pet- Wireless PIR Camera immune Detector Detector Wireless Indoor Wireless Outdoor Siren Siren Proximity GSM/GPRS Tags Communicator with PowerG Technology ALARM INTERNATIONAL SYSTEMS WWW.AIS-SECURITY.BE...

Table of Contents