Delivery Condition - Viessmann KOB Pyrot KRT Series Technical Data Manual

Krt 150 to krt 540 series wood-fired boiler
Table of Contents

Advertisement

Pyrot Technical Data

Delivery Condition

Standard delivery condition
The standard delivery condition of the Pyrot boiler
includes pre-assembled components as well as
components that need to be assembled by the contractor
in the field.
Components that are attached to the boiler at time of
delivery:
- The combustion chamber is mounted to the fire box
- Boiler is fully bricked
- Boiler door is mounted to the combustion chamber
including secondary air rotary blower
- Primary air vents are attached to the fire box
- Flue gas collector is attached to the tube heat
exchanger
- Pneumatic cleaning system (optional) is attached to
the flue gas collector
Measurements for the fire box as standard delivery condition
Boiler model
KRT150
Minimum size
47a in. x 78c in.
door
(1200 mm x
2000 mm)
Minimum ceiling
47a in. x 112a in.
opening (W x H)
(1200 mm x
2850 mm)
Minimum ceiling
47a in. x 128 in.
opening including
(1200 mm x
pneumatic
3250 mm)
cleaning system
Components that are not attached or installed to the
boiler at time of delivery (scope of the contractor):
- Electrical components which include temperature
sensors, oxygen sensor, light barriers for the fire box,
ignition blower, low water cut off, safety temperature
limiter, and light barriers for the complete extraction
system
- All wiring to the control cabinet
- Installation fittings which include pressure relief valve,
drain valve, temperature and pressure gauges
- Drive for the fire box grate is detached
- De-ashing system (optional) and drive for the de-ashing
system
- Air compressor (optional) and connection to the
pneumatic cleaning system (optional)
- The flue gas blower is not attached to the flue gas
collector
- Re-circulation system and insulation (optional)
- Flue gas de-duster (optional) comes in two pieces
- The in-feed auger is detached from the fire box
- Fire extinguishing system for the in-feed auger
- Slide valve (optional) or rotary valve (optional)
- All components of the extraction system (optional),
welding for flanges and support legs required
- Glass fiber insulation between any auger connections
KRT220
KRT300
59 in. x 88b in.
59 in. x 88b in.
(1500 mm x
(1500 mm x
2250 mm)
2250 mm)
59 in. x 112a in.
59 in. x 126 in.
(1500 mm x
(1500 mm x
3200 mm)
2850 mm)
59 in. x 128 in.
59 in. x 141c in.
(1500 mm x
(1500 mm x
3250 mm)
3600 mm)
General Information
KRT400
KRT540
70c in. x 98b in.
70c in. x 98b in.
(1800 mm x
(1800 mm x
2500 mm)
2500 mm)
70c in. x 130 in.
70c in. x 137c in.
(1800 mm x
(1800 mm x
3300 mm)
3500 mm)
70c in. x 145c in.
70c in. x 153b in.
(1800 mm x
(1800 mm x
3700 mm)
3900 mm)
5