American Dynamics MegaPower 3200 Release 2.0 Release Notes page 14

Table of Contents

Advertisement

Table 5, Known Defects continued
Defect
Description
1999
Displaying most any screen while
reading f/ CPU can cause EASY
data processing delays.
2007
Center Camera Titles defaults to left
if nothing is selected but it sets text
to right on screen.
2036
Alarms not activating a Salvo
correctly.
2053
Translation errors in recent
localization build.
2060
Camera Range and Monitor Range
not updating correctly after a factory
reset.
2061
File > New not clearing the Monitor
Status column.
2085
Satellite host port can be same for
multiple sites.
2097
ADMPCPU not updating DBVL card
after a factory reset. Fixing will
affect system performance.
2487
Localization - MPCPU A Selected &
MPCPU B Optional not localized for
any languages
2490
Definitions / Keyboard monitor
access custom range is not
changed when the number of
monitors is reduced
2496
Date & Time>>CPU date should be
in standard letters format
(MM/DD/YY)
2514
When you choose a language in the
options screen and reopen easy it
always reverts back to English in
the drop down menu
2519
The Error Log Status display screen
within the EASY CPU application
intermittently fails to update.
MEGAPOWER 3200 RELEASE 2.0
RELEASE NOTES
Work Around
Use a faster PC. Limit the maximum configuration size, display the System:
Options screen while reading the configuration file, and avoid displaying any
screens containing lots of data during the Read process.
After adding camera definitions, be sure to select a Center Title 1 and 2 choice
other than None from the dropdown menus for each camera to ensure proper
title placement. If you do not select a title justification after defining cameras,
then you must reselect the correct Center Title justification for each, save it to
file, and then Write the file to the MPCPU.
The monitor arming for Salvo was probably not armed correctly. Salvo alarm
callups require monitor block arming with only the lead (first) monitor being
armed with the desired contacts for the entire block of monitors.
Some translated strings are not available for certain languages in this release of
EASY CPU.
This function is working normally in this release, and the issue could not be
reproduced.
Restart the EASY application.
The user can delete the row on EASY CPU definitions/satellite sites.
After the user writes the config file to a Factory reset unit, they must follow it up
with a 107 F2. Depending on the size of the system, this command can take up
to 10 minutes to run.
The text "MPCPU A Selected & MPCPU B Optional" have not been translated to
Chinese or Korean.
This can be corrected by "writing" the configuration file to the ADMPCPU,
issuing a benign keyboard command to change a parameter (such as disabling a
non-existent or already disabled monitor's arming code with a 316-F2
command), waiting 5 minutes or more for the configuration file to be rebuilt, and
performing a "read" once again from the EASY CPU application.
The indication of the date standard is displayed but may show M/d/yyyy instead
of MM/DD/YY.
This defect only affects the language selection in the dropdown menu in the
options screen.
Recovery requires closing the EASY CPU application and launching it again. On
some networks, switching between the "Selected" and "Backup" CPUs can
sometimes take over 10 seconds to refresh the Error Log Status display.