Download Print this page

Known Limitations And Issues - American Dynamics Version 4.3 Software Update 3 Release Notes

For intellex ip

Advertisement

Intellex 4.30 Software Update 3 Release Notes
The table below highlights new known limitations or issues that were uncovered when testing
4.30 Software Update 3. The first group of issues are unique to the Bosch and VideoEdge
cameras, whereas the second group cover a wider range of cameras.
Known limitations and issues may exist from other releases. Please refer to the specific release
for the appropriate information.
Description
7275 - VEIPCH2: Appro IP PE R200 - Start
up issue with 16 Appro cameras assigned
7276 - VEIPCH2: Bosch -> Frames rates
returning a maximum of 15 ips for NTSC
cameras and 13 ips for PAL
7316 - VEIPCH2: Bosch: VG4-513-ECE2W -
Camera controls do not work the first time
you connect
7346 - VEIPCH2: Appro ADCIPEBPN -
Video loss on 16 camera overnight soak test
affecting only ADCIPEBPN
7391 - VEIPCH2: Appro Camera showing
green screen momentarily after viewing or
changing properties in IP sources
7338 - VEIPCH2: Appro cameras - Camera
Setup : Can use incorrect Username and
Password
7284 - VEIPCH2: Bosch: VG4-513-ECE2W -
Issues when attempting to create preset via
PTZ camera control
7305 - VEIPCH2: Appro IP PE860 - Video
feed not centred correctly in defined pane
for Appro cameras
7401 - VEIPCH2: Green screen issue
triggers alarm

Known Limitations and Issues

Suggested Work-Around
None
None
Please refer to the "Bosch VG4-500i Boot-up
Times" for more information.
Issue with IP PE860 – see "VideoEdge IP Camera
Performance" section above. Workaround is use
rate of 12FPS or 10FPS. Ensure updated drivers
installed. Enabled infrared functionality for
overnight conditions.
None
None
Exit preset OSD controls back to Iris/Focus OSD
controls and select either Iris for Yes or Focus for
No when camera requests confirmation on
screen. See "Bosch IP VG4-500i Messages"
section above.
Camera issue. Documented in "Centering Video
images" section above.
See section "Green flicker when startup or
changing settings" above. When alarms are set up
on a VideoEdge camera (Motion, Perimeter, Light
Change), and the user has clicked OK, the
momentary green screen can trigger an alarm,
Ignore this first alarm
8