Installation
The retaining plates A, B and C are
used to secure the cooker hood to the
wall.
First drill holes for fitting retaining plate
A.
22
– Before fitting the retaining plates
draw a centre line vertically on the
back wall at the selected position.
– Mark the measurement
cooking surface. This marks the
height of the lower rim of the cooker
hood.
– Drill two ø 8 mm holes, one at
100 mm and one at
the centre line for the retaining plate.
Insert S8 plugs.
above the
+
+ 425 mm on