b
protective shelf above
c
control unit
d
wall unit facia cut-out
e
cable in ducting
g
hob
h
cable to hob
i
additional connector box
j
protective shelf below
k
back wall of unit
For safety reasons, a protective shelf
must be installed as shown to ensure
that inadvertant contact with the hot
underside is prevented.
The distance between the lower
edge of the worktop and the upper
edge of the protective shelf must be
a minimum of 125 mm.
In order to ensure sufficient air circu-
lation, a gap of 20 mm must be left
between the protective shelf and
the rear panel of the base unit, and
a gap of 5 mm must be left between
the cabinet front panel and the
benchtop.