Maintenance indicator
Normal
TEMP.
Off
(temperature
warning)/
STATUS
indicator
LAMP
Green on
indicator
(Green
blinks
when the
lamp is
warming
up.)/
Orange on
(Eco)
Orange
blinks
(When the
lamp is
cooling.)
* For information about other types of blinking, contact your nearest Sharp Authorized Projector
Dealer or Service Center (see page 76).
Info
If the TEMP. (temperature warning)/STATUS indicator illuminates, and the projector enters Standby
mode, follow the possible solutions above and then wait until the projector has cooled down
completely before plugging in the power cord and turning the power back on. (At least 10 minutes.)
If the power is turned off for a brief moment due to power outage or some other cause while using
the projector, and the power supply recovers immediately after that, the LAMP indicator will
illuminate in red and the lamp may not be lit. In this case, unplug the power cord from the AC outlet,
replace the power cord in the AC outlet and then turn the power on again.
The cooling fan keeps the internal temperature of the projector constant and this function is
controlled automatically. The sound of the cooling fan may change during operation because the fan
speed may change and this is not a malfunction.
Problem
Abnormal
Red blinks The TEMP.
(temperature
warning)/STATUS
indicator blinks in
red when the
projector is on.
Red blinks
The internal
2 times
temperature is
(Repeatedly)
abnormally high.
Orange
blinks
Red blinks The lamp does
not illuminate.
Time to change
the lamp.
Red blinks
The lamp does
2 times
not illuminate.
(Repeatedly)
Red on
Time to change
the lamp.
Cause
The lamp unit cover
is open.
Temperatures
around the projector
are high.
Blocked air intake
Internal circuit
failure.
Cooling fan
breakdown
Internal circuit failure
Clogged air intake
No lamp
Remaining lamp life
becomes 5% or less.
The lamp is shut
down abnormally.
Burnt-out lamp
Lamp circuit failure
The lamp life is over.
Possible Solution
If the TEMP. (temperature
warning)/STATUS indicator
blinks in red even when the
lamp unit cover are
securely installed, contact
your nearest Sharp
Authorized Projector Dealer
or Service Center (see
page 76) for advice.
Use the projector in an
area with a temperature of
lower than 104°F (+40ºC).
Relocate the projector to
an area with proper
ventilation. (See page 8.)
Take the projector to your
nearest Sharp Authorized
Projector Dealer or Service
Center (see page 76) for
repair.
Install the lamp unit.
Disconnect the power cord
from the AC outlet, and
then connect it again.
Carefully replace the lamp.
(See page 66.)
Take the projector to your
nearest Sharp Authorized
Projector Dealer or Service
Center (see page 76) for
repair.
Please exercise care when
replacing the lamp.
Securely install the cover.