6
. (When selecting "Partition")
step
-2
Set the desired partition capacity.
Normal Recording Area: The area for normal
recording.
Alarm Recording Area: The area for alarm
recording.
Long Pre-Alarm Area: The area for long pre-
alarm recording.
• Set the partition capacity for each area in 5 %
unit.
• You cannot set "Normal Recording Area" to "0 %."
• When the setting is completed, return to the
screen of step 6-1 and then select "Next."
7. Select whether or not to make the recording
step
settings.
• To set the recording settings, select "Next."
• Select "Quit" to exit the setup wizard without
setting the recording settings. The power of the
unit turns on.
In the recording setting screens, you can return to the
previous screen by pressing the "Return" button.
8. (When selecting "Next")
step
By selecting "Execute," the unit automatically
checks the condition of the picture supplied from
the camera and then sets the camera number to be
recorded.
• Select "Next" when the setting is completed.
9. Set the recording time.
step
• Set the recording cycle and the recording hour
per day.
• Select "Execute" when the setting is completed.
10. Frame/field, recording rate, and the picture grade
step
for the camera numbers detected on step 8 are
automatically set.
• The settings made here are used for normal
recording.
• You can adjust the settings manually.
• Select "View" to confirm the settings. Select
"Next" when the setting is completed.
The audio recording is set to "Off." To record audio, refer
to
page 53.
When recording audio, the continuous recording time
becomes shorter than the time when recording only pic-
ture. Check the estimated recording time on the preview
screen of the normal recording.
11. Select "Finish" to exit setup wizard.
step
• The unit boots-up.
Setup Wizard