Frequency; Ping Speed (Advanced Mode Only) - Lowrance Elite 5 Operation Manual

Hide thumbs Also See for Elite 5:
Table of Contents

Advertisement

Sonar
Custom Range — Upper and Lower Limits
(Advanced Mode only)
Used to select the upper limit and lower limit of
a section of the water column. That allows you to
view a section of the water column that does not
include the water surface.
Upper and lower limits must be at least 6.5 ft (2m)
apart.
nOTe: When using a custom range, you
may not receive any digital depth read-
ings, or you may recieve incorrect depth
information.
SONAR combo.indb 18
Custom range menu

Frequency

Controls the transducer frequency used by the
unit. This unit supports two frequencies: 200kHz
and 83kHz.
Frequency menu
200 kHz has the highest sensitivity and best target
discrimination in shallow water. 83 kHz offers a
wider cone angle for more water coverage.

Ping Speed (Advanced Mode only)

Controls the rate the transducer uses to send sonar
waves into the water. Ping speed adjustments can
help reduce interference from other transducers.
When using fishing modes, ping speed settings are
optimized for the selected fishing conditions, so in
most cases, adjustments are not necessary.
18
9/15/2011 11:55:39 AM