Lowrance Elite-7x Operation Manual

Lowrance Elite-7x Operation Manual

Navico
Hide thumbs Also See for Elite-7x:

Advertisement

Elite-7x
Installation & Operation
Operation manual
manual

Advertisement

Table of Contents
loading

Summary of Contents for Lowrance Elite-7x

  • Page 1 Elite-7x Installation & Operation Operation manual manual...
  • Page 2 Part 15.103 of the FCC rules • complies with CE under RTTE directive 1999/5/EC • complies with the requirements of level 2 devices of the Radiocommunications (Electromagnetic Compatibility) standard 2008 For more information please refer to our website: www.lowrance.com.
  • Page 3 Warning The user is cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules.
  • Page 4: Table Of Contents

    Accessing the Settings menu ....5 Sonar Operation ......14 Accessing menu items......5 Trackback ..........14 Working with menus ........ 6 Sonar Menu ........... 14 Dialogs............. 6 Sensitivity ..........15 Entering text ..........6 Colorline ..........15 Table of Contents | Elite-7x...
  • Page 5 Downscan options ......... 19 Index ..........33 Sonar Settings ........20 Installation ..........21 DSI Operation ......... 23 Trackback ..........23 DSI menu..........23 Ping Speed ..........25 Downscan options ......... 25 Settings .......... 28 Settings menu........28 Table of Contents | Elite-7x...
  • Page 6: Introduction

    Conventional sonar and Downscan This unit supports two types of sonar: Conventional and Downscan. Refer to the Sonar Operation section for information about conventional sonar features and settings. Downscan features and settings are covered in the Downscan Operation section. Introduction | Elite-7x...
  • Page 7: Basic Operation

    Setup wizard, restore defaults. Page menus The Downscan and Sonar pages have menus that can only be accessed when those pages are Pages displayed. This unit has three pages: Downscan, Sonar and Sonar/Downscan. Downscan page Pages dialog Downscan menu Basic Operation | Elite-7x...
  • Page 8: Accessing The Settings Menu

    Horizontal panel Two-panel page Press the PAGeS key twice to switch active panels. The page menu for active page will be displayed when the MenU key is pressed. Basic Operation | Elite-7x...
  • Page 9: Working With Menus

    EntEr to turn it on/off. Some functions, like naming a waypoint, route or trail, will require you to input text. Dropdown menus Access the dropdown menu and press the keypad up/ down to select the desired item and press EntEr. Basic Operation | Elite-7x...
  • Page 10: Fishing Modes

    2. Repeat Step 1 for each character. unit by providing preset packages of sonar settings geared to specific fishing conditions. 3. When entry is completed, highlight OK and press EntEr. Switches letters to uppercase/ lowercase Switches keyboard between Alpha and QWERTY layout Basic Operation | Elite-7x...
  • Page 11: Cursor

    Units (Enables distance, speed, depth, 400ft or less Ice fishing temperature, and bearings options) NOTE: Use Fresh Water mode when fishing in less than 100 feet of water; otherwise your unit may not track bottom properly. Basic Operation | Elite-7x...
  • Page 12: Restore Defaults

    Press the Pwr/LIGhT key to access the Backlight dialog. Select Standby and press enTer. Press any key to resume normal operation. nOTe: Leaving your unit in Standby mode when your boat is not is use will run down your battery. Basic Operation | Elite-7x...
  • Page 13: Sonar Page

    Displays the water column moving from right to moving from right to left. You can overlay downscan left on your unit’s screen. sonar on the conventional sonar page by selecting Dowscan Overlay on the Sonar settings menu. Pages | Elite-7x...
  • Page 14: Combo Pages

    (side) or horizontally (over). Highlight a combo page on the Page dialog and press MenU. Sonar/Downscan Sonar/Dowscan Select the desired configuration and press enTer. horitzontal nOTe: Press the PAGeS key twice to switch active panels. Pages | Elite-7x...
  • Page 15: Overlay Data

    6. Select the desired data and press enTer. 7. Press MenU and select Return to Overlays. Press enTer. Configure 8. Press MenU, select Done Configuring Allows you to select/customize overlay data. and press enTer. Pages | Elite-7x...
  • Page 16 2. Select the data type and press the menu will appear. keypad to the right. 3. Highlight the desired data source and Data sources press enTer. Used to select the network device that will supply source data for a selected data type. Pages | Elite-7x...
  • Page 17: Sonar Operation

    Exit cursor mode. The features described in this section are for conventional sonar. Sonar Menu Refer to the Dowscan operation section for Press MenU from any sonar information on Dowscan features. page to access the Sonar menu. Sonar Operation | Elite-7x...
  • Page 18: Sensitivity

    Auto Sensitivity Keeps sensitivity at a level that works well under Adjust most conditions, reducing the needs for adjust- ments. Auto Sensitivity is turned on by default. Used to make adjustments to Sensitivity and Colorline/Grayscale. Sonar Operation | Elite-7x...
  • Page 19: Range

    83 kHz offers a view a section of the water column that does not wider cone angle for more water coverage. include the water surface. Upper and lower limits must be at least 6.5 ft (2m) apart. Sonar Operation | Elite-7x...
  • Page 20: Ping Speed

    Noise Rejection Uses advanced signal processing to monitor the ef- fects noise (boat pumps, water conditions, engine ignition systems, etc.) has on your display, and then filters out undesired signals. Sonar Operation | Elite-7x...
  • Page 21: Fish Id

    Split Zoom Split Flasher Color Allows you to change the look of the display using palettes with varying degrees of color/brightness. Sonar Operation | Elite-7x...
  • Page 22: Downscan Options

    Allows you to select data to be displayed on top of the nOTe: The Downscan options menu Sonar page. will only be available when Downscan Overlay data setup is covered overlay is enabled. in the Pages section. Overlay data Sonar Operation | Elite-7x...
  • Page 23: Sonar Settings

    That allows the display to continue smooth scrolling if the bottom depth is out of transducer range. wArnInG: Manual mode should only be used by advanced sonar users. Sonar Operation | Elite-7x...
  • Page 24: Installation

    Before setting keel offset, measure Resets selected fishing mode to default settings. That is useful when you want to clear settings adjustments made while using a fishing mode. Transducer Keel Keel Offset (-3.5 feet) Sonar Operation | Elite-7x...
  • Page 25 Calibrates a paddlewheel speed sensor with speed your unit. data from a GPS source. Temperature calibration Calibrates data from the transducer temperature sensor with data from a known temperature source to ensure the accuracy of temperature information. Sonar Operation | Elite-7x...
  • Page 26: Dsi Operation

    You can review your sonar history by pressing the keypad to the left until the screen starts to move in reverse and the sonar history bar appears at the bottom of the screen. DSI history bar Stops sonar transmission; pauses sonar scroll DSI Operation | Elite-7x...
  • Page 27 60 to 80 Upper and lower limits must be at least 6.5 ft (2m) DSI units do not have a Sensitivity setting like apart. traditional sonar units. Contrast functions as the sensitivity setting for DSI units. DSI Operation | Elite-7x...
  • Page 28: Ping Speed

    Controls the rate the transducer uses to send sonar waves into the water. Ping speed adjustments can ignition systems, etc.) has on your display, and then filters out undesired signals. help reduce interference from other transducers. DSI Operation | Elite-7x...
  • Page 29 Low. set to High. suspended targets and structure. Split Zoom nOTe: Sonar history (Trackback) will not be recorded when sonar is stopped. Changes the display to a split zoom view. DSI Operation | Elite-7x...
  • Page 30 Allows you to select data to be displayed on top of the DSI page. Overlay data setup is covered Overlay data in the Pages section. Settings Accesses the Settings menu. Refer to “Sonar Set- tings” on page 20. DSI Operation | Elite-7x...
  • Page 31: Settings

    Accesses installation and configuration settings for your unit. Enables advanced features and settings System menu Displays software (Advanced mode information only) Restores settings Settings and options to fac- menu tory default settings (Advanced mode only) Settings | Elite-7x...
  • Page 32: About

    About screen. Selects the language used on menus and text boxes. Lowrance periodically updates unit software to add features and improve functionality. To see the latest available software version go to www. Audio lowrance.com.
  • Page 33 Advanced Mode With the unit connected to a NMEA 2000 network, you can select a GPS antenna on the network as your GPS source, and share newly created way- points with other display units on the network. Settings | Elite-7x...
  • Page 34 Simulator options menu. with units on that network. Data sources Allows you to select the source this unit will use for GPS data. Device list Used to view data for devices connected to your NMEA 2000 network. Settings | Elite-7x...
  • Page 35: Specifications

    NMEA 0183 Output Transducer cable 20ft (6m) Declaration of Part 15.103 FCC rules & CE RTTE Conformity directive 1999/5/EC Power Transmit Power 250W RMS Power Requirement Voltage Input 10 to 17V Current drain Typical: 1.1A Fuse type 3-amp Automotive Specifications | Elite-7x...
  • Page 36: Index

    NMEA 2000 30 Reset Fishing Mode 21 Cursor 8 Data sources 31 Ice Mode 19 Reset water distance 22 Custom Range 16, 24 Noise Rejection 17, 25 Installation menu 21 Saving Screenshots 29 Depth Range 24 On/Off features 6 Index | Elite-7x...
  • Page 37 Sonar Page 10 Working with menus 6 Sonar settings 20 Split Flasher 18 Split Zoom 17 Standby mode 9 Stop Sonar 19, 26 Surface Clarity , 18 System settings 28 Temp calibration 22 Text entry 6 Trackback 23 Index | Elite-7x...
  • Page 39 Contact information Customer Service: 1-800-628-4487 (8 a.m. to 5 p.m. Central Standard Time, M-F) (Canada) 1-855-361-1564 canada@navico.com (8 a.m. to 5 p.m. Eastern Standard Time, M-F) Ordering Accessories http://store.navico.com/ Visit our website www.lowrance.com...
  • Page 40 Visit our website: www.lowrance.com *988-10428-001* N2584...

Table of Contents