Superior BC36MH Installation Instructions Manual page 6

Wood-burning fireplaces
Table of Contents

Advertisement

Optional
Floor
Bracket
1-1/2"
Figure 8
Figure 9
step 3. Refer to fireplace drawings and speci-
fications on Pages 6 and 7 for framing dimen-
sions and details. Frame appliance enclosure
as illustrated in Figure 13.
WARNINg
under no circumstances can the
fireplace top spacers (see Figure
12) be removed or modified, nor
may you notch the header to fit
around or be installed lower
than the spacers. the header
may be in direct contact with
the top spacers but may not be
supported by them.
Note: The framed depth, 20-5/8" (524 mm) from
a framed wall, must always be measured from
a finished surface. If a wall covering such as
drywall is to be attached to the rear wall, then
the 20-5/8" (524 mm) must be measured from
the drywall surface. It is important that this
dimension be exact.
If the appliance is to be elevated above floor
level, a solid continuous platform must be
constructed.
The header may rest on the top metal spacers,
but must not be notched to fit around them.
Consult all local codes.
6
Metal Safety Strips
Framing dimensions for ceiling
Flue type
FtF8, Vertical
Blocking
FtF8, Vertical
FtF8 offset 30°
FtF8 offset 30°
Metal Safety Strips
Figure 10
step 4. Fireplace should be secured to side
framing members using the nailing tabs at the
top and bottom of the fireplace front face.
Pitch
0/12
6/12
12/12
* Perpendicular to roof ridge
Figure 11
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
A
Ceiling Framing
Inches (millimeters)
A
B
14-1/2"
14-1/2"
(368 mm)
(368 mm)
16-1/2"
16-1/2"
at 2"
(419 mm)
(419 mm)
14-1/2"
25"
(368 mm)
(635 mm)
16-1/2"
27"
at 2"
(419 mm)
(686 mm)
D
Framing dimensions for Roof
Inches (millimeters)
FtF8 at 1" (USA)
c
14-1/2" (368 mm)
14-1/2" (368 mm)
14-1/2" (368 mm)
17" (432 mm)
14-1/2" (368 mm)
21-1/2" (546 mm) 16-1/2" (419 mm)
Use screws, 8d nails or equivalent fasteners
(Figure 12). This manufactured home model
is also provided with floor brackets used to
secure the fireplace to the floor to prevent
shifting in transit.
B
Note: The use of floor brackets are optional.
They are included (unbent) inside the Com-
bustion Air Kit package, located inside the
firebox. Refer to Figure 8 for suggested
bracket placement.
Figure 12
C
Roof Framing
FtF8 at 2" (CANADA)
d*
c
16-1/2" (419 mm)
16-1/2" (419 mm)
Screw, 8d
Nail Or
Equivalent
Fastener
d*
16-1/2" (419 mm)
19" (483 mm)
23-1/2" (597 mm)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: