Insulate Joists
Same As Ceiling
Draft Stops
Firestop
CTDT
Termination
Note: Non-
Combustible
Chase
Flashing
Must Be
Used To
Cover
Chase
Opening
8'
Level
Insulation
(Thermal Barrier)
Figure 2
Chimney Enclosure
Construct a box-like framed structure to enclose
the fireplace and chimney within the confines
of the manufactured home, not necessarily
above the roof line.
As with all chimney installations, avoid overhead
obstructions such as trees, power lines, etc.
The chimney/fireplace enclosure should be
constructed and insulated just like any outside
wall. In a cold climate, we recommend the base
of the chimney/fireplace enclosure should also
be insulated between the solid continuous floor
beneath the fireplace and the chase bottom.
Insulation in a cold climate installation is not
required for safety.
Note: Local codes may not require firestopping
at the ceiling levels for outside chimney enclo-
sure installations. However, it is recommended
for safety and the reduction of heat loss.
4
Do not obstruct the collar open-
ings around the base of the chim-
n
y e
a
t t
e h
Do not insulate the chimney
enclosure cavity with blown or
fill type insulation materials.

ASSEMBLY OUTLINE

Before You Start
Check your inventory list to be sure you have
all the necessary parts supplied in good us-
able condition. Check also for any concealed
damage.
Check the operation of the damper. The dam-
per is controlled through the use of a damper
rod inside the top center of the firebox open-
ing, behind the lintel (Figure 3 ).
Optional
• To CLOSE the damper, pull the damper rod
Insulation
FORWARD (toward the front of the fireplace),
In Outside
Walls Of
then slide LEFT until locked in position.
Chase
• To OPEN the damper, pull the damper rod
FORWARD (toward the front of the fireplace),
Solid
then slide RIGHT until locked in position.
Continuous
Surface
Damper Rod
Outside
Base
Damper
CLOSED
To adjust damper, PULL damper rod
FORWARD (toward front of fireplace),
then slide all the way LEFT (CLOSED) or
RIGHT (OPEN), until locked in position.
Damper Rod in LEFT (CLOSED) Position
Figure 3
LOCATION OF THE FIREPLACE
Carefully select the proper location for heat
circulation, aesthetics, chimney obstructions
and clearance to side wall(s). With proper pre-
planning, a slight adjustment of a few inches
can save considerable time and expense later
during construction and assembly.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
WARNING
t
p o
o
t f
e h
e r
l p
c a
. e
Lintel
Damper
OPEN
Combustion Air Actuator
[DETAIL/CUTAWAY]
Hearth
Hearth
Figure 4
WARNING
This fireplace and chimney
system is not approved for use
in a bedroom or any room used
for sleeping.
Carefully consider the position of the fireplace
opening with respect to the location of adjacent
or nearby stairwells, bath or kitchen exhaust fans
and/or return air registers for forced air furnaces/air
conditioners that could cause a smoking fireplace
condition if the house is tightly insulated.
When locating the fireplace, consideration must
be given to combustibles and final finishing. See
Figure 5 and confine the final location of com-
bustible finish materials to the "Safe Zone".
Do NOT permanently place furniture or other
items such as decorative pillows within 60" of
the fireplace front face.
Do NOT cover black part of frame
with combustible materials.
12"
45°
1"
Door
Opening
Safe
12"
Zone
Figure 5
Wall
Covering

Hide quick links: