Specifications - Sennheiser SKP 100 Instruction Manual

Plug-on transmitter
Hide thumbs Also See for SKP 100:
Table of Contents

Advertisement

Specifications

RF characteristics
Modulation
Frequency ranges
Transmission frequencies
Switching bandwidth
Nominal/peak deviation
Frequency stability
RF output power at 50 Ω
Pilot tone squelch
AF characteristics
Compander system
AF frequency response
Signal-to-noise ratio
(1 mV RF, peak deviation)
THD
Max. input voltage
Input impedance
Adjustment range of input
sensitivity
Overall device
Temperature range
Power supply
Nominal voltage
Power consumption
• at nominal voltage
• with switched-off
transmitter
Operating time
Dimensions
Weight (incl. batteries)
In compliance with
Europe
Approved by
Canada
USA
wideband FM
516–558, 566–608, 626–668,
734–776, 780–822, 823–865 MHz
(A to E, G, see page 3)
1,680 frequencies,
tuneable in steps of 25 kHz
20 frequency banks, each with up to
12 factory-preset channels
1 frequency bank with up to
12 user programmable channels
42 MHz
±24 kHz/±48 kHz
≤ ± 15 ppm
typ. 30 mW
can be switched off
Sennheiser
HDX
80–18,000 Hz
≥ 110 dBA
≤ 0.9%
3.3 V
rms
60 kΩ, unbalanced
48 dB,
adjustable in steps of 6 dB
–10°C to + 55°C
2 AA size batteries, 1.5 V
or BA 2015 accupack
2.4 V
typ. 180 mA
≤ 25 μA
typ. 8 hrs
approx. 105 mm x 43 mm x 43 mm
approx. 195 g
EMC
EN 301489-1/-9
Radio
EN 300422-1/-2
Safety
EN 60065
EN 62311 (SAR)
Industry Canada RSS 123
IC: 2099A-G3SKP
limited to 806 MHz
FCC-Part 74
FCC-ID: DMOG3SKP
limited to 698 MHz
Specifications
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Skp 100 g3

Table of Contents