Specifications - Sennheiser ew 100 G3 Series Instruction Manual

Hide thumbs Also See for ew 100 G3 Series:
Table of Contents

Advertisement

All manuals and user guides at all-guides.com

Specifications

RF characteristics
Modulation
wideband FM
Frequency ranges
516–558, 566–608, 626–668, 734–776,
780–822, 823–865 MHz
(A to E, G, see page 3)
Transmission frequencies
1,680 frequencies, tuneable in steps of
25 kHz
20 frequency banks, each with up to 12
factory-preset channels
1 frequency bank with up to 12 user
programmable channels
Switching bandwidth
42 MHz
Nominal/peak deviation
±24 kHz/±48 kHz
≤ ±15 ppm
Frequency stability
RF output power at 50 Ω
typ. 30 mW
Pilot tone squelch
can be switched off
AF characteristics
Compander system
Sennheiser
AF frequency response
80–18,000 Hz
≥ 110 dBA
Signal-to-noise ratio
(1 mV RF, peak deviation)
≤0.9 %
THD
Max. input voltage
3.3 V
Input impedance
60 kΩ, unbalanced
Adjustment range of input
48 dB, adjustable in steps of 6 dB
sensitivity
Overall device
Temperature range
–10 °C to + 55 °C
Power supply
2 AA size batteries, 1.5 V
or BA 2015 accupack
Nominal voltage
2.4 V
Power consumption
• at nominal voltage
typ. 180 mA
≤25 µA
• with switched-off plug-on
transmitter
Operating time
typ. 8 hrs
Dimensions
approx. 105 mm x 43 mm x 43 mm
Weight (incl. batteries)
approx. 195 g
In compliance with
Europe
EMC
Radio
Safety
Approved by
Canada
Industry Canada RSS 123
IC: 2099A-G3SKP
limited to 806 MHz
USA
FCC-Part 74
FCC-ID: DMOG3SKP
limited to 698 MHz
Specifications
HDX
rms
EN 301489-1/-9
EN 300422-1/-2
EN 60065
EN 62311 (SAR)
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Skp 100 g3

Table of Contents