Medalist Pro 2160N, Rev. B
Additional drive options
Figure 7. Options jumper settings
The options jumper block allows you to configure your drive for
several additional configuration options. The drawing in Figure 7
shows how to place jumpers to enable each optional feature. A
brief description of each option is included.
Parity Enable. Parity is enabled when a jumper is installed on
pins 7 and 8 (default). To disable parity, remove this jumper.
Motor Start Enable. The Motor Start option causes the drive to
wait for a Start/Stop Unit command from the host before starting
or stopping the spindle motor. Motor start is enabled when a
jumper is installed on pins 11 and 12.
13
11 9 7 5 3 1
14
12 10 8 6 4 2
Parity Enabled
Parity Disabled
Motor Start Enabled
Motor Start Disabled
Remote LED
connection
15