Pseudorandom Bit Sequence (PRBS) Testing
To test using the internal Pseudorandom Bit Sequence source, ensure that the Central
Office and the Customer Premises equipment are configured for loopback. The
iMcV-DS3/E3/STS-LineTerm modules should be set to normal default mode. On the
HOST iMcV-DS3/E3/STS-LineTerm module, set the Transmit Coax Data Source to
"Transmit Pseudorandom Sequence" (S1-6, S1-7=OFF). Verify the PRBS LED comes
ON at the HOST iMcV-DS3/E3/STS-LineTerm module to validate the coax wire
connections to the Central Office. Verify the PRBS LED comes ON at the REMOTE
iMcV-DS3 module to validate the coax wire connections at the Customer Premises
equipment and the fiber line going to the REMOTE iMcV-DS3/E3/STS-LineTerm
module. The fiber line returning from the remote iMcV-DS3/E3/STS-LineTerm
module is validated by verifying the RM LED is ON at the HOST iMcV-DS3/E3/STS-
LineTerm module. At this point all connections for the channel have been
verified.