All Cast Surround; Blower Cord Installation - Left Side; Exploded Drawings - Quadra-Fire VOYA-GRAND-MBK Owner's Manual

Voyageur grand wood insert automatic combustion control (acc)
Hide thumbs Also See for VOYA-GRAND-MBK:
Table of Contents

Advertisement

R
H. All Cast Surround Kit
Size: 40 in. W x 30 in. H
Included in Surround Kit: (2) side pieces, left and right; (1)
l top piece; (1) fastener package.
Tools Needed: Powered 4 to 6 inches long Phillips head
screw driver; pliers
1. Remove contents from box being careful not to scratch or
damage the cast trim pieces.
Lay surround pieces face down on a protected surface to
2.
prevent scratching
.
3. Align the bosses on the top piece to the holes on the side
pieces. Secure the 3 pieces together.
4. Attach the mounting brackets to the side pieces included with
the kit. Figure 43.1.
5. In order to get a tight seal for the surround, you must reposition
a side shield. There are two holes on the shield and it will come
from the factory secured in the first (left) hole. Remove the
shield and re-install using the second (right) hole. Figure 43.2.
5. Position the trim on the appliance matching up the mounting
brackets with the slots on the appliance.
6. Attach the surround to the appliance 2 screws.
DO NOT OVERTIGHTEN SCREWS - MAY DAMAGE
PROCELAIN FINISH.
4 Mounting Brackets
Figure 43.1
Mounting
Brackets
Attach to Appliance
with Screws
Do not overtighten - may
damage porcelain finish
Figure 43.2
May 23, 2013
Remove and Reposition
Side Shield using Second
Hole
7075-166C
VOYAGEUR GRAND Wood Insert
I. Blower Cord Installation on Left Side
The blower cord is shipped to be installed on the right side
of the appliance. You may relocate the cord so it is on the
left side.
Overview: You are removing the power cord from the
blower controls, re-routing the cord to the left side and re-
installing the power cord to the blower controls. Refer to
the exploded drawing on page 44.
Figure 43.3
1. Swing the grille down to expose the 2 bolts, one
at each end. Remove the bolts and pull blower
access assembly away from appliance and store
away from your work area.
Figure 43.4
2. Remove the 2 screws in the hold down bracket in
front of the blower assembly. You do not need to
remove the blower from the hold down bracket.
3. Disconnect the 2 blower wires that are attached
to the wire harness and pull the blower assembly
away from the appliance.