Euromaid Dishwasher Assembly And Disassembly Manual

Key components
Hide thumbs Also See for Dishwasher:

Advertisement

ASSEMBLY AND DISASSEMBLY METHODS FOR KEY
1) DRAIN HOSE
The position of the drain hose during the
assembly of the product.
machine in the desired position.
When the hose is to be replaced, the unit, which is seen at the right back top
corner of the machine is required to be removed after being cut.
3 wire clamps and 2 plastic hose clamps are removed for dismantling the
drain hose.
2) TOP PLATE
Manner of opening the latch of the upper
plate.
The plate is pulled back for approximately 1 cm. by pressing the latches
located at both sides of the upper plate in upward direction. Afterwards, the
plate is removed by pulling it upwards.
COMPONENTS
Supply hoses before disassembling.
For the purpose of avoiding any
siphonage in the drain hose, the
hose is kept at a certain sufficient
level by means of 1 hose clamp.
This clamp should never be
removed while assembling the
Manner of removing the upper plate after the
Position of the Drain and Water
latches are released.

Advertisement

Table of Contents
loading

Summary of Contents for Euromaid Dishwasher

  • Page 1 ASSEMBLY AND DISASSEMBLY METHODS FOR KEY COMPONENTS 1) DRAIN HOSE Position of the Drain and Water Supply hoses before disassembling. For the purpose of avoiding any siphonage in the drain hose, the hose is kept at a certain sufficient The position of the drain hose during the level by means of 1 hose clamp.
  • Page 2: Control Panel

    In case the machine is to be installed under the counter, the support of the upper plate should be dismantled. 3) CONTROL PANEL The control panel is detached from the inner metal plate, after unscrewing the 6 screws located on the front side of the inner door, as is seen at the photo. 4) TOP PLATE MID SUPPORT The part can be dissembled by loosening 2 snops screw driver...
  • Page 3: Display Group

    Release the 3 snap fits in order to open the cover of the card holder. In order to dismantle the main card pull out the sockets assembled to the card.Then bend the snap fits and pull out the main card. As the main card is removed the leds are easily dismantled.
  • Page 4: On-Off Button Key Holder

    7) ON-OFF BUTTON KEY HOLDER The key holder is fixed to the panel back structure by snap fits. The key cap should be mounted before the holder assembled to the panel back structure 8) FAN GROUP The Fan motor is located under the contsruction and over the heater.
  • Page 5: Bottom Tray

    9) BOTTOM TRAY While providing service to the components located beneath the machine, the machine is moved to a place other than the place of installation. For dismantling the tray, the machine is inclined backwards with an angle of approximately 40˚. The door is swiftly opened and the plastic cover located at the bottom of the machine is taken out, by being...
  • Page 6: Overflow Gauge

    10) OVERFLOW GAUGE The mechanism attaching the overflow gauge to the base is pulled to the front direction, by pressing the latches and then is taken out. 11) DRAIN PUMP The notch is opened and turned in the counter clockwise direction and taken out by rotating it 10-15˚.
  • Page 7: Circulation Pump

    13) HEATER Pipe type heater is used in the machine. It is taken out by unscrewing the two spring clamps. 14) CIRCULATION PUMP After the clamps and cable connections of the circulation pump are removed, the screws of the motor holding plate connected to the body frame are unscrewed.
  • Page 8: Side Walls

    15) FEEDING PIPE OF THE UPPER SPRAY ARM AND FILTER SUPPORT Filter support is freed after the related screw is loosened. After the notch of the feeding pipe of the upper spray arm is released, both of the parts are taken out.
  • Page 9 17) REGENERATION CONTAINER The 2 metal notches are released through a screwdriver. The lid of the regeneration container is taken out by being rotated in the counter clockwise direction at 5-10˚. 18) FLOW-METER The electronic counter on the flowmeter located at the left lower corner of the regeneration container, is taken out as demonstrated in the photo and detached from the socket.
  • Page 10: Hinge Plates

    19) HINGE PLATES 3 screws on the both sides are loosened. 2 screws on the both sides of the connection sheet of the hinge arm are unscrewed and the plates are removed. 20) DETERGENT CONTAINER The inner door plate, held by 8 notches, is taken out by releasing the lobes.
  • Page 11 21) CABLE CASE To replace any cable, the cable case is opened and the replacement is made. 22) CONCRETE SHEET Both of the sidewalls are dismantled. A total of 4 screws connecting the concrete sheet to the frames from both sides are unscrewed. 2 screws that connect the base to the concrete sheet are unscrewed.
  • Page 12 To render services to these components, the operators should work on the backside of the machine. The concrete sheet should be removed. The hose holder is taken out by turning as it is seen in the picture. 30 cm The drain hose holder is made up two symmetric parts, which fit together by the help of the snaps, and should be located approximately 30 cm from the hose end.
  • Page 13: Three Way Valve

    For dismantling the interference filter and the main power cable first of all dismantle the sockets. Unscrew the screw mounted on the main power cable holder and release the cable. Then unscrew the two screws, assembling the interference filter and the concrete sheet.
  • Page 14: Upper Spray Arm

    25) FOOTS The notch in the middle is pressed by a screwdriver. 26) UPPER SPRAY ARM First follow the instructions given for the top plate. After disassembling the top plate, loosen the nut by turning to counter clockwise direction. Press the snaps of upper spray arm group &...
  • Page 15: Bottom Layout

    BOTTOM LAYOUT The inner tub differs because of the change made for the new sump, and sump connections . Sump Gasket Sump o-ring is placed between the sump and the inner tub in order to prevent New filter support part is fixed to the sump leakage and inner tub by the screws numbered as 3, 4 and 5.
  • Page 16 3W valve should be fixed to the sump by PT screws, for the DW models that have 3 way valve. The flow diverter is assembled to the sump by hot plate, for the DW models that have flow diverter. This is default for factory outlet, and no serviceability for the flow diverter alone.
  • Page 17 The filtering system will be effective if the assembly of the filters are done in the right manner. For both the metal and plastic filter, the filter ends should be positioned under the related region of the flow diverter.

Table of Contents