OPERATION

Before you begin programming your thermostat, you should
be familiar with its features and with the display and the loca-
tion and operation of the thermostat buttons. Your thermostat
consists of two parts: the thermostat cover and the base. To
remove the cover, pull it straight out from the base. To replace
the cover, line up the cover with the base and press until the
cover snaps onto the base.
The Thermostat Buttons and Switches
1 Raises temperature setting.
2 Lowers temperature setting.
3 TIME button.
4 PRGM (program) button.
5 RUN (run program) button.
6 HOLD temperature button.
7 FAN switch (ON, AUTO).
8 SYSTEM switch (COOL, OFF, HEAT).

The Display

9 Indicates day of the week.
10 Flame icon ( ) is displayed when the SYSTEM switch
is in the HEAT position. Snowflake icon ( )is displayed
(non-flashing) when the SYSTEM switch is in the COOL
position.Snowflake is displayed (flashing) if the thermostat
is in lockout mode to prevent the compressor from cycling
too quickly.
11 Displays "BATT" or "CHANGE
batteries are low and should be replaced. Only "BATT" or
"CHANGE
" and "LO" in the minutes field are displayed
when batteries are low with no system power.
12 Alternately displays current time and temperature. Displays
"LO" in the minutes field when batteries are low.
13 The word "HOLD" is displayed when the thermostat is in
the HOLD mode. "HOLD" is displayed flashing when the
thermostat is in a temporary HOLD Mode.
14 Displays currently programmed set temperature (this is
blank when SYSTEM switch is in the OFF position).
15 Displays "FLTR" when the system has run for the pro-
grammed filter time period as a reminder to change or clean
your air filter.

CONFIGURATION MENU

The configuration menu allows you to set certain thermostat
operating characteristics to your system or personal require-
ments.
Press RUN to make sure the thermostat is in the run program
mode, then press PRGM and RUN at the same time to enter
the configuration menu. The display will show the first item in
the configuration menu.
The configuration menu table summarizes the configuration
options. An explanation of each option follows.
4
Press HOLD to change to the next menu item or press TIME
to go backwards to the previous item in the menu. To exit the
menu and return to the program operation, press RUN.If no keys
are pressed within fifteen minutes, the thermostat will revert to
normal operation.
1) Select Temporary Hold Time - The thermostat can hold any
" when the 2 "AA"
temperature you set it to for the amount of time you select on
this option.Your choices are 0:00 to 8:00 hours in 15 minute
increments. 0:00 disables the function
Example:
1. You have selected 3:00 hours for the Temporary Hold
2. With the thermostat set to Heat or Cool, press HOLD
3. After releasing the button, "HOLD" on the display will
4. Use
2) Select FA or SL (Fast or Slow) Heating Cycle Rate - The
FA setting is frequently used for gas, oil or electric heat. The
SL setting produces a longer heating cycle which is normally
for hot water or steam (hydronic) systems. Both settings
produce very accurate temperature control and can be set
to your personal preference. FA cycles the system just under
1°F and the SL setting cycles at approximately 1.5°F.
3) Select backlit display - The display backlight improves
display contrast in low lighting conditions.Selecting backlight
ON will keep the light on for a short period of time after any
key is pressed. Selecting OFF will keep the light off.
time period.
for approximately five seconds until HOLD time (3:00
indicating 3 hours) appears as a setting reminder.
blink.
or
to set the temperature to your prefer-
ence. The thermostat will maintain this temperature
setting for 3 hours with "HOLD" blinking to remind you
it is in Temporary Hold. After 3 hours the thermostat will
go back to the program temperature and "HOLD" will
no longer blink or display.
CHANGE