Heat & Glo 6000CMOD-IPI Owner's Manual
Hide thumbs Also See for 6000CMOD-IPI:
Table of Contents

Advertisement

Models:
6000CMOD-IPI
8000CMOD-IPI
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions
and the manufactured home construction and safety standard,
Title 24 CFR, Part 3280 or Standard for Installation in Mobile
Homes, CAN/CSA Z240MH, in Canada.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13
Owner's Manual
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
Installation and Operation
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo 6000CMOD-IPI

  • Page 1 Technologies suggests NFI certifi ed or factory trained This appliance is only for use with the type(s) of gas indicated professionals, or technicians supervised by an NFI on the rating plate. certifi ed professional. Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 2: Congratulations

    00,000 00,000 00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX XXXXXXXX XXXXXXXX (Serie): (Serie): Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 3: Table Of Contents

    D. Mantel and Wall Projections ..... . . 22 F. Wall Switch Installation for Fan (Optional) ... . 46 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 4 D. Contact Information ......71  = Contains updated information. Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 5: Limited Lifetime Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645F 02-18-13 Page 1 of 2 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 6 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645F 02-18-13 Page 2 of 2 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 7: Listing And Code Approvals

    • A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 9: User Guide

    (NOT SHOWN) SECTION 2.E. FIXED GLASS ASSEMBLY (NOT SHOWN) SECTION 14.G. MANTEL SECTION 5.D FAN KIT SECTION 2.C. HEARTH CLEAR SPACE SECTION 2.D. Figure 2.1 General Operating Parts Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 10: Fan Kit (Optional)

    Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information refer to the instructions supplied with your decorative door or front. Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 11: Ipi Battery Tray/Battery Installation

    See Section H. WARNING! Risk of Fire or Asphyxiation! DO NOT op- erate fi replace with fi xed glass assembly removed. Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 12: Lighting Instructions (Ipi)

    For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Final inspection by Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 13: After Fireplace Is Lit

    In a standing pilot system the pilot will always stay on. It is normal for the glass rock media to change color slightly over the lifetime of the Glass rock media color change appliance. Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 14: Maintenance And Service

    • Check that louvers are not blocked. • Inspect fi xed glass assembly for scratches and nicks that • Vacuum and dust surfaces. can lead to breakage when exposed to heat. Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 15 • Remove all foreign objects. • Verify unobstructed air circulation. Burner Ignition and Operation Frequency: Annually By: Qualifi ed Service Technician (Either cobrahead or SIT) Figure 3.1 IPI Pilot Flame Patterns Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 16: Glass Refractory, Base Pan, Burner And Valve Assembly Removal

    MAY VARY REAR PANEL RETAINER SIDE PANEL RETAINERS Figure 3.4 Base Pan Removal Figure 3.2 Remove Glass Panel Retainers Figure 3.5 Burner Assembly Removal Figure 3.3 Glass Panel Removal Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 17: Burner Identifi Cation

    Appearance of valve components may vary. 6000CMOD-IPI (NG) 6000CMOD-IPI (LP) Figure 3.7 Valve Assembly Removal Figure 3.6 Valve Assembly Removal 8000CMOD-IPI (NG) 8000CMOD-IPI (LP) Figure 3.8 Valve Assembly Removal Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 18: Installer Guide

    FRAMING HEADED OFF IN CEILING JOISTS (SECTION 8.C) OPTIONAL WALL SWITCH (SECTION 12.C) MANTEL AND MANTEL LEG (SECTION 5.D) SURROUND HEARTH EXTENSION GAS LINE (SECTION 11) Figure 4.1 Typical System Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 19: Design And Installation Considerations

    Flat blade screwdriver 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws One 1/4 in. female connection (for optional fan). Caulking material (300ºF minimum continuous exposure rating) Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 20: Framing And Clearances

    ONE 90º ELBOW 17-3/4 See Section D. 6000 Mantel Projections 1295 1067 1829 55-7/8 19-3/4 See Section D. 8000 Mantel Projections 1419 1245 2007 Figure 5.1 Appliance Locations Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 21: Constructing The Appliance Chase

    Appliance (Width) (Height) (Depth) (Width) 40-1/8 6000 1019 1067 42-1/8 8000 1070 1245 * Adjust framing dimensions for interior sheathing (such as sheetrock) Figure 5.2 Clearances to Combustibles Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 22: Mantel And Wall Projections

    Figure 5.6 Door Overlaps Surround FIREPLACE OPENING MANTEL LEG OR WALL PROJECTIONS minimum is ____, then maximum is_____. 2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16 Inches Millimeters  Inches  Millimeters Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 23: Termination Locations

    Over 16/12 to 18/12 ..........7.0 Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 24 Figure 6.3 Minimum Clearances for Termination • Vinyl protection kits are suggested for use with vinyl siding. Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 25: Vent Information And Diagrams

    DVP6 DVP12 Effective Height/Length DVP24 DVP36 DVP48 1219 DVP6A 3 to 6 76 to 152 DVP12A 3 to 12 76 to 305 Figure 7.2 DVP Pipe Effective Length Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 26: Vent Diagrams

    90º elbow, to allow the vent pipe to clear the top standoffs. Figure 7.3 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 27 = 1 ft. (305 mm) Minimum = 40 ft. (12.2 m) Maximum = 20 ft. (6.0 m) Maximum = 1 ft. (305 mm) Minimum INSTALLED HORIZONTALLY Figure 7.4 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 28 914 mm 16 ft * 4.9 m* 3 ft. 914 mm 14 ft.* 4.3 m* = 20 ft. (6.1 m) Maximum = 40 ft. (12.2 m) Maximum Figure 7.5 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 29 2. Break the fl ue restrictor into two pieces. Do this by bending the part back and forth until it breaks (see Figure 7.8). BREAK HERE Figure 7.6 Figure 7.8 Flue Restrictor Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 30 1.2 m 20 ft. 6.1 m = 50 ft. (15.2 m) Maximum *No specifi c restrictions on this value EXCEPT cannot exceed 50 ft (15.2 m) Figure 7.11 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 31 4 ft. 1.2 m 18 ft. 5.5 m 18 ft. 5.5 m = 20 ft. (6.1 m) Maximum = 40 ft. (12.2 m) Maximum INSTALLED HORIZONTALLY Figure 7.12 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 32: Vent Clearances And Framing

    * Shows center of vent framing hole for top or rear venting. The center of the hole is one (1) in. (25.4 mm) above the center of the horizontal vent pipe. Figure 8.2 Wall Penetration Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 33: Install The Ceiling Firestop

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM 3 FASTENERS PER SIDE CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.4 Installing the Attic Shield Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 34: Install Attic Insulation Shield

    These tabs must be used to prevent blown insulation from getting between the shield and vent pipe, and to Figure 8.6 Heat Zone Cover Plate maintain air space clearance. Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 35: Appliance Preparation

    3. Secure the fi rst section of venting to the fi rebox by at- taching to the starting collar with screws. See Figure 9.4. Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 36: Installing The Non-Combustible Board

    • Secure the appliance to the framing by using nails or screws through the nailing tabs. • Secure the appliance to the fl oor by inserting two screws through the pilot holes at the bottom of the appliance. Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 37: Installing Vent Pipe (Dvp And Slp Pipe)

    fl ue at the horizontal elbow joint to prevent the elbow from rotating. Use screws no longer than 1/2 in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. INCORRECT Figure 10.4 Seams Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 38: Assemble Vent Sections (Slp Pipe Only)

    • Only outer pipes are sealed, sealing the inner fl ue is not Figure 10.5 Adding Venting Components required. • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 39: Secure The Vent Sections

    Figure 10.10 Rotate Seams for Disassembly connection point to appliance. 120º Figure 10.11 Align and Disassemble Vent Sections Figure 10.8 Securing Vertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 40: Install Decorative Ceiling Components (Slp Only)

    fl aps and the roof. Figure 10.13 WARNING! Risk of Fire! Clean out ALL materials from inside the support box and complete the vertical vent run and termination. Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 41: Install Metal Roof Flashing

    • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Figure 10.17 Assembling the Storm Collar Around the Pipe Figure 10.17 Assembling the Storm Collar Around the Pipe Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 42: Install Vertical Termination Cap

    • Once the pipe section and the termination cap have been connected, slide the wall thimble up to the interior wall surface and attach with screws provided. See Figure 10.24. Figure 10.24 Wall Thimble Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 43: Install Horizontal Termination Cap (Dvp And Slp Pipe)

    DVP-TRAP1 can adjust 1-1/2 in. (3-1/8 to 4-5/8 in.) DVP-TRAP2 can adjust 4 in. (5-3/8 to 9-3/8) DVP-HPC1 can adjust 2-1/8 in. (4-1/4 to 6-3/8) DVP-HPC2 can adjust 4-1/8 in. (6-3/8 to 10-1/2) Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 44: Gas Information

    fl exible gas connector are connected to the 1/2 in. (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 45: Electrical Information

    TO JUNCTION BOX (110V) MODULE FLAME MODULATION RC100 RC200 RC300 (OPTIONAL WALL CONTROLS) BATTERY PACK 6V DC THERMOSTAT WIRE ASSEMBLY / WALL SWITCH WIRE Figure 12.1 IPI Wiring Diagram Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 46: Electrical Service And Repair

    Figure 12.3 Junction Box Wired to Wall Switch or BC10 leg) wire, route it through the knockout in the face of the junction box, and connect to the top fan switch connector (1/4 in. male) as shown. Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 47: Finishing

    Figure 13.4 Door Overlaps Surround 2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16 Inches Millimeters  Inches  Millimeters Figure 13.2 Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening) Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 48: Facing Material

    Oil-based or standard acrylic paints may dis- color due to heat exposure. inches 39-3/4 6000 millimeters 1010 1041 inches 41-3/4 8000 millimeters 1060 1219 Figure 13.5 Noncombustible Facing Diagram Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 49: Door Selection

    CMOD DOOR WALL NOTE: THE APPLIANCE MUST BE ELEVATED A MINIMUM OF 1 INCH IN ORDER TO USE THE CMOD DOOR. Figure 13.7 Appliance Installed Off the Floor Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 50 (TOP EDGE) Finishing materials 1 inch maximum thick. Stop fi nishing material fl ush with opening. NON-COMBUSTIBLE FINISHING MATERIAL Figure 13.8 Finishing Material 1 Inch Thick or Less Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 51 B = Top of door to bottom of fi replace. D = Bottom of Finishing Material to Bottom of Fireplace Figure 13.9 Finishing Material Thickness Greater Than One Inch Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 52: Appliance Setup

    2. Slide the side glass panels in positions as shown in Figure 14.2. 3. Figure 14.3. shows the glass panels installed properly. Figure 14.3 Install Side Retainers REAR RETAINER Figure 14.1 Install Rear Retainer Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 53: Media Placement

    See Figure 14.6. Store the rock fi xture assembly under the appliance for future use. Figure 14.6 Remove Rock Fixture Assembly Figure 14.4 Rock Fixture Installed Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 54 PILOT OPENING (WHITE AREA) Figure 14.7 Placement of Media BURNER NO MEDIA ON PILOT OPENING (WHITE AREA) Figure 14.8 Placement of Media Figure 14.9 Proper Placement of Media Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 55: Fixed Glass Assembly

    • Install optional trim kits and/or surrounds using the instructions included with the accessory. • Use non-combustible materials to cover the gap between the sheet rock and the appliance (when applicable to the model). Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 56: Troubleshooting

    D. Pilot valve solenoid. Verify that 1.5 to 1.8 VDC is supplied to pilot solenoid from module. If below 1.5 volts, replace module. If 1.5 volts or greater, replace valve. Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 57 ON position. If there is no spark at “I” terminal module must be replaced. If there is a spark at “I” terminal, module is fi ne. Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 58: Reference Materials

    Millimeters Location Inches Millimeters 1041 36-1/8 11-11/16 28-1/2 33-1/2 14-1/4 34-5/8 8-1/2 2-1/4 2-7/8 9-11/16 26-7/8 8-1/2 6 dia 39-7/8 1013 40-7/8 1038 Figure 16.1 Appliance Dimensions-6000 Models Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 59 Inches Millimeters Location Inches Millimeters 1219 11-11/16 43-1/8 1096 35-1/2 35-1/2 17-3/4 36-5/8 2-3/8 8-1/2 2-7/8 9-15/16 28-7/8 8-1/2 41-7/8 1064 42-7/8 1089 Figure 16.2 Appliance Dimensions-8000 Models Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 60: Vent Components Diagrams

    14 in. (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 16.2 DVP vent components Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 61 79 mm 117 mm Length DVP-TRAP 5-3/8 in. 9-3/8 in. Trap2 Horizontal Termination Cap 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 DVP-HPC1 DVP-HPC2 Figure 16.3 DVP vent components Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 62 13-7/8 in. 9-1/2 in. 26 in. (352 mm) (241 mm) 660 mm 14 in. (356 mm) DVP-HSM-B Extended Heat Shield DRC-RADIUS Figure 16.4 DVP vent components Cap Shield Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 63 1 in. (25 mm) (222 mm) 7-3/4 to 10-3/8 in. (197 to 264 mm) 1-5/8 in. (41 mm) DVP-FBHT FireBrickTermination Cap DVP-HPC High Performance Cap Figure 16.5 DVP vent components Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 64 (233 mm) 13-5/8 IN. 16-11/16 IN. 16-11/16 IN. (346 mm) 424 mm (424 mm) SLP-LPC 12-1/2 IN. (318 mm) SLP Low Profi le Cap Figure 16.6 Vent Components Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 65 51 - 152 Adapter SLP12A 2 - 12 51 - 305 SLP PIPE SLP-HVS SLP-FS SLP-WS Horizontal Pipe Ceiling Firestop Wall Shield Firestop Support Figure 16.7 SLP Series Vent Components Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 66 Termination Cap Support Box-Black Termination Cap 26 in. 660 mm DVP-HSM-B DVP-2SL Extended Heat Shield Adapter SLP-DCF-BK SLP-WT-BK Ceiling Firestop Wall Thimble-Black Black Figure 16.8 SLP Series Vent Components Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 67: Service Parts

    Qty 2 req 2241-201 Pkg of 25 Glass Retainer Clips 060-235-25 Surround Assembly 2166-019 Glass Assembly GLA-6000G Junction box 4021-013 Additional service part numbers on following page. 4/13 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 68 Qty 2 req 2242-201 Glass Retainer Clips Pkg of 25 060-235-25 Surround Assembly 2170-019 Glass Assembly GLA-950TR Junction box 4021-013 Additional service part numbers on following page. 4/13 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 69 Orifi ce, NG (#40C) 582-840 6000CMOD-IPI Orifi ce, LP (#55C) 582-855 Orifi ce, NG (#35C) 582-835 8000CMOD-IPI Orifi ce, LP (#54C) 582-854 Additional service part numbers on following page. Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 70 Conversion Kit, LP LPKI-6CM Conversion Kit, NG 8000CMOD-IPI Conversion Kit, LP LPKI-8CM Pilot Orifi ce, NG 593-528 Pilot Orifi ce, LP 593-527 Regulator, NG NGK-DXV-50 Regulator, LP LPK-DXV-50 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...
  • Page 71: Contact Information

    5890485, 5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945B Printed in U.S.A. - Copyright 2013 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev. i • 4/13...

This manual is also suitable for:

8000cmod-ipi

Table of Contents