D. Junction Box Installation
If the box is being wired from the OUTSIDE of the
appliance:
• Remove the cover plate located on the outer shell
- right side (see Figure 10.2).
• Install the supplied Romex™ connector in the cover
plate.
• Feed the necessary length of wire through the
connector.
• Make all necessary wire connections and reattach
the cover plate to the outer shell.
If the box is being wired from the INSIDE of the
appliance:
• Remove the screw attaching the junction box/
receptacle to the outer shell, rotate the junction
box inward to disengage it from the outer shell (see
Figure 10.2).
• Pull the electrical wires from outside the appliance
through this opening into the valve compartment.
IGNITION MODULE 3 VAC
LOW VOLTAGE
SEE NOTE 1
REMOTE
CONTROL
HOT
RED
3 VAC
Heat & Glo • Soho24B • 2137-900 Rev. P • 8/12
ORG
WHT
GROUND TO
FIREPLACE
CHASSIS*
ORG
BLK
VALVE
REMOTE
JUMPER WIRE
Note: Appliance will not operate unless properly grounded.
Figure 10.2 Junction Box Detail
• Feed the necessary length of wire through the connector.
• Make all necessary wire connections to the junction box/
receptacle and reassemble the junction box/receptacle to the
outer shell.
INTERMITTENT
PILOT IGNITOR
THERMOSTAT
WIRE
ASSEMBLY
Romex
Connector
Cover Plate
outside firebox
Copper
ground attached
GRN wire
to GRN screw with
inside box
GRN wire
NOTE: Do NOT wire
110VAC to wall switch.
14/2WG
31