Heat & Glo EXCLAIM-42H-C Owner's Manual
Heat & Glo EXCLAIM-42H-C Owner's Manual

Heat & Glo EXCLAIM-42H-C Owner's Manual

Installation and operation

Advertisement

Quick Links

Models:
EXCLAIM-42H-C
EXCLAIM-42T-C
Woodburning Fireplace
Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING
If the information in these instruc-
tions is not followed exactly, a
re may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not over re. Over ring will void your war-
ranty.
• Comply with all minimum clearances to
combustibles as speci ed. Failure to
comply may cause house re.
Installation and service of this replace should
be performed by quali ed personnel. Hearth
& Home Technologies suggests NFI certi ed
or factory-trained professionals, or technicians
supervised by an NFI certified
professional.
(Traditional refractory shown.)
CAUTION
DO NOT DISCARD THIS MANUAL
Read, understand
and follow these
instructions for safe
i n s t a l l a t i o n a n d
operation.
Heat & Glo • EXCLAIM-42C • 4013-094 Rev I • 10/06
Owner's Manual
Installation and Operation
Leave this manual with
party responsible for
use and operation.
WARNING
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
Glass and other surfaces are hot
during operation and cool down.
Keep children away.
CAREFULLY SUPERVISE children in same room
as replace.
Alert children and adults to hazards of high
temperatures.
Keep clothing, furniture, draperies and other
combustibles away.
WARNING
Fire Risk
For use with solid wood fuel or decorative
gas appliance only.
Do not install unvented gas logs.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo EXCLAIM-42H-C

  • Page 1 Owner’s Manual Installation and Operation Models: EXCLAIM-42H-C EXCLAIM-42T-C Woodburning Fireplace (Traditional refractory shown.) CAUTION DO NOT DISCARD THIS MANUAL • Read, understand • Leave this manual with • Important operating and follow these party responsible for a n d m a i n t e n a n c e instructions for safe use and operation.
  • Page 2 Read this manual before installing or operating this replace. Please retain this owner’s manual for future reference. Congratulations! Congratulations on selecting a Heat & Glo wood burning re- The information contained in this owner’s manual unless noted place. The Heat & Glo replace you have selected is designed otherwise, applies to all models and gas control systems.
  • Page 3: Table Of Contents

    Table of Contents Listing and Code Approvals Accessories A. Appliance Certi cation ......4 A. Gas Log/Lighter Provisions ....27 Getting Started Finishing A.
  • Page 4: Listing And Code Approvals

    Listing and Code Approvals A. Appliance Certi cation WARNING This replace system has been tested and listed in accor- dance with UL 127 and ULC-S610 standards by Underwrit- Improper installation, adjustment, alteration, service ers Laboratories Inc. for installation and operation in the or maintenance can cause injury or property damage.
  • Page 5: Getting Started

    Getting Started A. Design and Installation Considerations CAUTION WARNING Check building codes prior to installation. Asphyxiation Risk • Installation MUST comply with local, regional, Negative pressure can cause spillage of state and national codes and regulations. combustion fumes and soot. Fire needs to draft •...
  • Page 6 Location of the replace and chimney will affect performance. As shown in Figure 2.1 the chimney should: • Be installed through the warm airspace enclosed by the building envelope. This helps to produce more draft, especially during lighting and die-down of the re. •...
  • Page 7: Typical Fireplace System

    C. Typical Fireplace System The Heat & Glo replace system consists of the following: • Fireplace/integral grate/refractory/outside air system • Refractory • Chimney termination cap • Chimney system • Hearth extension Optional components include: • Glass doors • Chimney air kit (required in Canada) Additional lateral Termination cap support for chimney...
  • Page 8: Tools And Supplies Needed

    D. Tools and Supplies Needed E. Inspect Fireplace and Components WARNING Before beginning the installation be sure the following tools and building supplies are available: Fire Risk Reciprocating saw Framing material Explosion Risk Pliers High temp caulking material Inspect fireplace and components for damage.
  • Page 9: Framing And Clearances

    Framing and Clearances WARNING Note: • Illustrations and photos re ect typical installations Fire Risk and are FOR DESIGN PURPOSES ONLY. Provide adequate clearances.• Around air • Illustrations/diagrams are not drawn to scale. openings • Actual installation/appearance may vary due to •...
  • Page 10: Clearances

    B. Clearances WARNING Fire Risk • Comply with all minimum clearances to combustibles as speci ed. • Framing or nishing material used on the front of, or in front of, the appliance closer than the minimums listed, must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc.).
  • Page 11: Sidewalls/Surrounds

    C. Sidewalls/Surrounds Adjacent combustible side walls must be located a minimum of 24 in. (610 mm) from the replace opening. See Figure 3.3. If you are using a decorative surround constructed of combustible material, it must be located within the shaded area de- ned in Figure 3.3.
  • Page 12: Construct The Chase

    E. Construct the Chase Gas line holes and other openings should be caulked with high temperature caulk or stuffed with unfaced berglass in- A chase is a vertical boxlike structure built to enclose the re- sulation. If the replace is being installed on a cement slab, place and/or its vent system.
  • Page 13: Installation Of Fireplace

    Installation of Fireplace WARNING CAUTION Fire Risk Sharp Edges Asphyxiation Risk • Wear protective gloves and safety glasses Do not draw outside combustion air from: during installation. • Wall, oor or ceiling cavity. • Enclosed space such as an attic or garage.
  • Page 14 Handle left - open Handle right - closed Attic insulation shield may be used to keep 3 ft min. from top of insulation away from Figure 4.4 Locating the Outside Air Control uppermost chimney chimney. section to air inlet. Note: Chimney air kit is required in Canada. Ceiling firestop on floor of attic.
  • Page 15: Secure The Fireplace

    B. Secure the Fireplace • Remove smoke shield by removing ve screws. See Figure 4.7. Smoke shield is located at top of replace • Position the Fireplace front. This replace may be placed on either a combustible or • Remove screens by removing screw from the end of each noncombustible continuous at surface.
  • Page 16 • Remove replace from pallet. The replace is attached • Install back refractory, making sure refractory is to pallet with two brackets on each side and rear of outer centered and notches are to the bottom of rebox. Place shell. See Figure 4.11. Remove screws from bracket, pallet grate brackets in outer two notches of refractory.
  • Page 17 • Place grate into grate brackets. See Figure 4.17. Note: To ensure proper installation, gas knockouts in the side • Replace smoke shield. refractory should be positioned towards back of replace. See Figure 4.15. GRATE BRACKET KNOCKOUT Figure 4.17 Grate Secured in Grate Bracket •...
  • Page 18: Place The Protective Metal Hearth Strips

    D. Place the Protective Metal Hearth Strips WARNING Fire Risk! • Metal hearth strips MUST be installed. Sparks or embers may ignite ooring. Included with your replace you will nd two metal hearth strips measuring approximately 26 in. x 4 in. (660 mm x 102 mm). These strips are used to provide added protection where the replace and the hearth extension meet.
  • Page 19: Chimney Assembly

    Chimney Assembly Termination Cap Chimney must extend beyond combustible roof structure Additional support for Maintain minimum tall chimneys height of chimney above roof Storm Collar Install roof flashing Maintain minimum according to minimum clearances to requirements combustibles as specified Offsets/returns may not exceed Support straps for offsets/ 30°...
  • Page 20: Chimney Requirements

    A. Chimney Requirements To determine the chimney components needed to complete Vertical distances are measured from the base of the re- your particular installation, follow the steps below: place as shown in Figure 5.2. • Determine the total vertical height of the fireplace installation.
  • Page 21: Using Offsets/Returns

    B. Using Offsets/Returns To bypass any overhead obstructions, the chimney may be • Measure how far the chimney needs to be shifted to enable offset using an offset/return. it to avoid the overhead obstacle. See Figure 5.3. Use dimension “A” to determine chimney section required to An offset and return may be attached together or a chimney achieve the needed shift.
  • Page 22: Assemble The Chimney Sections

    C. Assemble the Chimney Sections Note: The ceiling restop MUST be nailed to the bottom Attach either a straight chimney section or an offset to the of the ceiling joists EXCEPT when the space above is uninsulated and the attic insulation shield is not being used top of the replace (depending on your installation require- (see Figure 5.5).
  • Page 23: Install The Attic Insulation Shield

    E. Install the Attic Insulation Shield An insulation shield must be installed when there is a pos- Tabs sibility of insulation coming into contact with the factory built chimney system. 17 in. (423 mm) 24 in. Attic • Bend the tabs at the top of the attic insulation shield inward. (610 mm) Insulation This will help keep the chimney section centered in the...
  • Page 24: Complete The Enclosure

    Complete the Enclosure A. Chimney Termination Chimney Termination Requirements (See Figures 6.1 and 6.2) • Must have a cap approved and listed for this replace system • Must not be located where it will become plugged by snow or other material •...
  • Page 25: Chase Top

    Install the Chimney Air Kit (required in Canada) • Install the chimney sections up through the chase enclosure. When using a TR444 Round Termination When installing the chimney air kit, follow the instructions Cap, the uppermost top section of pipe must extend 6 in. provided with this accessory.
  • Page 26 • For installations utilizing an ST475 Square Termination Cap the last chimney section must not be more than 4-1/2 in. (114 mm) below the chase top. See Figure 6.7. Flashing Collar Cap Standoff 2 in. (51 mm) min. 1-1/2 in. 4-1/2 in.
  • Page 27: Accessories

    Accessories A. Gas Log/Lighter Provisions WARNING A certi ed gas log lighter or decorative gas log set can be installed in this replace. Asphyxiation Risk • Maximum input is 100,000 BTU/hr. • Damper must be locked open when gas logs •...
  • Page 28: Finishing

    Finishing A. Hearth Extension A hearth extension must be installed with all replaces to protect the combustible oor in front of the replace from both radiant heat and sparks. See Figures 8.1 -8.4. High temperature (300°F min.) continuous, non-combustible sealant HX3 or HX4 Hearth Ext Tile, stone or other...
  • Page 29 Note: Maximum height from floor under fireplace to top of finished hearth extension is 7-5/8 in. (195 mm) 20 in. (508 mm) Min. Hearth Extension Floor 12 in. 20 in. Min. Min. 12 in. Min. Micore Hearth Strip Noncombustible Material Figure 8.3 Raised Hearth Extension Note: Maximum height from floor...
  • Page 30: Finishing Material

    B. Finishing Material WARNING • Combustible Material Material which is made of or surfaced with wood, Fire Risk compressed paper, plant bers, plastics, or any material Do NOT obstruct air inlets. capable of igniting and burning, whether ame proofed or Do NOT modify air inlets.
  • Page 31: Operating Instructions

    Operating Instructions WARNING WARNING HOT! DO NOT TOUCH. Fire Risk SEVERE BURNS MAY RESULT. • Do not operate fireplace before CLOTHING IGNITION MAY RESULT. reading and understanding operating Glass and other surfaces are hot during instructions. operation and cool down. Failure to operate replace properly may cause re.
  • Page 32: Outside Air

    B. Outside Air E. Firescreen A source of air (oxygen) is required in order for combustion A rescreen is always provided to control sparks. It must to take place. Whatever air is consumed by the re must be be closed whenever the replace is in use. Glass doors or replaced through cracks around windows, under doors, etc.
  • Page 33: Grate

    G. Grate Seasoning Seasoned rewood is nothing more than wood that is The factory installed integral grate must be used to hold the cut to size, split and air dried to a moisture content of logs from falling out of an open replace and to allow air to around 20%.
  • Page 34: Starting A Fire

    I. Starting a Fire CAUTION Check the ue damper to be certain it is in the full open po- sition. Place crumpled or twisted paper under the replace Odors and vapors released during initial grate. Loosely arrange kindling or small pieces of wood to operation.
  • Page 35: Troubleshooting

    Troubleshooting This replace will operate correctly only if adequate ventila- ue, or some condition is in effect to draw smoke from the tion is provided to allow proper draft to the replace system. replace into the house. Understanding and differentiating Hearth &...
  • Page 36: Diagnostics And Problem Solving

    B. Diagnostics and Problem Solving I can’t get a good re going. What am I doing wrong? Diagnostic Questions Solutions Possible Causes of Condition Is the damper open? • No draft Open damper. Is there enough paper/starter? • Insuf cient heat to ignite kindling Use more paper/starter.
  • Page 37 The replace burns the wood too fast. What can I do? Diagnostic Questions Solutions Possible Causes of Condition Do you have glass doors? • Need to slow air intake Add glass doors. What is the condition of the • Extremely dry wood Mix in less seasoned wood after re established.
  • Page 38: Maintenance And Servicing The Fireplace

    11 11 Maintenance and Servicing the Fireplace A. Disposal of Ashes B. Chimney Inspection/Cleaning Ashes should be placed in a metal container with a tight- t- Inspect the chimney internally for obstructions and construc- ting lid. The closed container of ashes should be placed on tion damage.
  • Page 39: Maintenance Task List

    CAUTION WARNING Handle glass assembly with care. Asphyxiation Risk When cleaning glass door: Fire Risk • Avoid striking, scratching or slamming Annual inspection by qualified technician glass. recommended. • Do NOT use abrasive cleaners. Check: • Use a hard water deposit glass cleaner on •...
  • Page 40: Reference Materials

    Reference Materials A. Fireplace Dimensions 34-1/2 in. (876 mm) 9-1/2 in. (241 mm) 27-1/2 in. (699 mm) 50-1/2 in. (1283 mm) 71-3/4 in. (1822 mm) (effective height) Outside Air 59-1/4 in. (1505 mm) 49-5/8 in. 28-1/2 in. Gas Knockout Knockout (1260 mm) (724 mm) 43-1/8 in.
  • Page 41: Fireplace Components

    B. Fireplace Components Catalog # Description EXCLAIM-42H-C Fireplace with Integral Grate, Outside air Kit, Hearth Protection Strips and Herringbone Pattern Refractory EXCLAIM-42T-C Fireplace with Integral Grate, Outside air Kit, Hearth Protection Strips and Traditional Brick Pattern Refractory DM8042 Glass Doors - Bi-fold, Clear-View - Black...
  • Page 42: Chimney Components

    C. Chimney Components The following pictures show only those chimney components which may be safely used with this replace. ID4 Insulated Duct Catalog # Description 4 in. (102 mm) i.d. CAK5A Chimney Air Kit (required in Canada) Insulated Duct/Outside Air 42 in.
  • Page 43 Inside Diameter 10 in. (254mm) 17 in. (432 mm) 21 in. (533 mm) Outside Diameter 13 in. (330 mm) Ceiling restop Catalog # FS538 0-deg. 17 in. 432 mm FS540 30-deg. 26 in. 660 mm SL430 Offset/Return 17 in. (432 mm) 15-1/4 in.
  • Page 44 72 in. 36 in. (1829 mm) (914 mm) 15-3/4 in. 13-3/8 in. (400 mm) (340 mm) TR444 Round Termination Cap 2 in. (51 mm) CT56 Chase Top 34-3/4 in. (883 mm) 32-1/2 in. (826 mm) Decorative Shroud LDS33/LDS46 TR442 Round Telescoping Termination Cap Catalog # LDS33 8-1/2...
  • Page 45 Woodburning Termination Cap TR342 / 344 TV TR342 / 344 TS345 / 445 TR11 / 11T TV Shroud TR11 / 11T TR442 / 444 TV (Top Vent) TR442 / 444 (with TR-TVK installed) (with TR-TVK installed) OPEN TOP with solid sides and 3 in. opening at the bottom. 32 X 32 with Minimum Base Dimensions 28 X 28 with...
  • Page 46: Service Parts

    This page intentionally left blank. Heat & Glo • EXCLAIM-42C • 4013-094 Rev I • 10/06...
  • Page 47 This page intentionally left blank. Heat & Glo • EXCLAIM-42C • 4013-094 Rev I • 10/06...
  • Page 48 This page intentionally left blank. Heat & Glo • EXCLAIM-42C • 4013-094 Rev I • 10/06...
  • Page 49: Limited Warranty

    E. Limited Warranty WARRANTY FOR HEAT & GLO FIREPLACES The limited warranty will not become effective until you have mailed the completed warranty card to: Hearth & Home Technologies Inc. 20802 Kensington Blvd., Lakeville, MN 55044. This card must be mailed within 60 days of the fireplace installation. Subject to the conditions set forth herein, HEARTH &...
  • Page 50: Contact Information

    F. Contact Information Hearth & Home Technologies Inc. 800 W. Jefferson Lake City, MN 55041 Please contact your Heat & Glo dealer with any questions or concerns. For the number of your nearest Heat & Glo dealer, please visit www.heatnglo.com. –...