Install Fireplace & Chimney; Install Chase Top - Heatilator EL36 Series Owner's Manual

Installation and operation
Hide thumbs Also See for EL36 Series:
Table of Contents

Advertisement

B. Install Fireplace & Chimney
Install as per Sections 7 and 8.
C. Install Chase Top
You MUST use a chase top in a chase installation. Chase
tops are available from your Heatilator dealer or may be
field constructed.
Include a turndown and drip edge to prevent water from
seeping into the chase.
Include a 2 in. (51 mm) soldered, welded or spun collar
around pipe opening to keep water out.
Provide a 1/8 in. (3 mm) gap around the flue pipe.
Slope the chase top downward away from the
opening.
WARNING! Risk of Fire! DO NOT caulk the pipe to the
chase top collar.
Caulk all seams to prevent leaks.
Refer to Figure 9.3.
Heatilator • EL36/EL42 • 4044-132 • Rev AD• 7/12
Slope Downward
(1/4 in. per foot
minimum)
Figure 9.3
Chase Top Construction
2 in. (51 mm) Collar
on Chase Top
Turn-down
Drip Edge
Chase
.018 (26 ga) min.
Galvanized
Chase Top
33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

El42 seriesEl42 series

Table of Contents