Performance Data Sheet - GE Profile 23 Owner's Manual And Installation

Hide thumbs Also See for Profile 23:
Table of Contents

Advertisement

Available languages

Available languages

Performance
Data Sheet
SmartWater Filtration System
GWF / HWF Cartridge
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.*
(100% safety factors built in for unmetered usage)
Parameter
Chlorine
T&O
Particulate**
Standard
No. 53: Health
Effects
USEPA
MCL
Standard N o.42:Aesthetic Effects
Influent
Effluent
Challenge
Concentration
Average
Maximum
2.0 mgiL+
10%
0.02 ppm
0.05 ppm
ut least 10,000 purticles/mL
3,978
7,800
% Reduction
Average
Minimum
98.90%
97.37%
98.00%
96.10%
Min. Required
Reduction
> 50%
> 85%
Parameter
Maximum
Turbiditg
0.1 NTU
Cgsts
55
Lead ut pH 6.5
i ppb
Lead ut pH 8.5
4.3 ppb
Lindune
0.00005 ppm
Atruzine
0.003 ppm
2,4-D
0.090 ppm
Asbestos
1.2 MFLiml
USEPA
MCL
1 NTU***
99.95% Reduction
15 ppb
15 ppb
0.0002ppm
0.003ppm
0.100ppm
99%
Influent
Challenge
Concentration
11 + 1 NTU***
Hinimum
50,000 L
0.15 mg/L+
10%
0.15 mg/L+
10%
0.002 mgiL+
10%
0.009 mgiL+
10%
0.210 mgiL+
10%
107 to 108 fibers/L;
fibers greater than
10 micrometers
in length
Effluent
Average
0.07 NTU
26
i ppb
1.8 ppb
0.00005 ppm
0.002 ppm
0.042 ppm
0.32 HFL/ml
% Reduction
Average
Minimum
99.71%
99.59%
99.97%
99.95%
99.37%
99.37%
98.8%
97.13%
91.93%
91.93%
76.19%
64.28%
84.89%
67.63%
99.95%
99.82%
Min. Required
Reduction
0.5 NTU
> 99.95%
0.010 mg/L
0.010 mg/L
0.0002 mg/L
0.003 mg/L
0.07 mg/L
99%
* Tested using a flow rate ofO.5 gpm; pressure
of 60 psig; pH of 7.5 +_0.5; temp. of 20 ° +_2.5°C
** Measurement
in Particles/mt.
Particles used were 0.5-!
microns
*** NTU=Nephelometric
Turbiditg
units
Operating
Specifications
• CapacitLl:certified for up to 300 gallons (1135 I);up to six months for models without a replacement filter indicator light; up to one
Llear for models with a replacement filter indicator light
• Pressure requirement: 40-120 psi (2.8-8.2 bur), non-shock
• Temperature: 33-100°F (0.6-38°C)
• Flow rate: 0.5 gpm (1.9 Ipm)
General Installation/Operation/Maintenance
Requirements
• Flush new cartridge at full flow for 3 minutes to purge out trapped air.
• Replace cartridge when flow becomes too slow.
Special Notices
• Installation instructions, parts and service availabilitLl, and standard warrantLl are included with the product when shipped.
• This drinking water sLlstem must be maintained according to manufacturer's instructions, including replacement of filter
cartridges.
• Do not use with water that is microbiologicallLl unsafe or of unknown qualitLl without adequate disinfection before or after
the sLlstem. SLlstems certified for cLlst reduction malt be used on disinfected water that mall contain filterable cllsts.
• The contaminants or other substances removed or reduced bll this water treatment sllstem are not necessarilll in llour water.
• Check for compliance with the state and local laws and regulations.
• Note that while the testing was performed under standard laboratorll conditions, actual performance mall varll.
Sllstems must be installed and operated in accordance with manufacturer's recommended procedures and guidelines.
Sgstem Tested and Certified bg NSF International against ANSIiNSF Standard 42 & 53 for the
reduction of:
Standard No. 42: Aesthetic Effects
Chemical Unit
Taste and Odor Reduction
Chlorine Reduction
Mechanical Filtration Unit
Particulate Reduction, Class I
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead and Atrazine Reduction
Lindane and 2,4-D Reduction
Mechanical Filtration Unit
Turbidit9 Reduction
Cgst and Asbestos Reduction
Hanufactured for: General Electric Compang, Louisville, KY40225