Gas Requirements - Fisher & Paykel Intuitive DEIX2 Installation Instructions And User Manual

Fisher & paykel installation instructions and user guide clothes dryer
Hide thumbs Also See for Intuitive DEIX2:
Table of Contents

Advertisement

Available languages

Available languages

Gas Requirements (Gas Models Only)
The installation must conform with Local Codes, or in the absence of Local Codes, to the National
Fuel Gas Code ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code,
CSA B149.1.
Gas type
Your dryer must have the correct burner for the type of gas in your home. Burner information is
located on the rating plate located on the rear of the console. If this information does not agree
with the type of gas available in your home, contact your local Fisher & Paykel supplier or service
center.
Natural Gas
This dryer is supplied ready for use with Natural Gas.
It is design certified by UL International for LP (Propane or Butane) Gases with the appropriate
conversion.
LP Gas Conversion
If the dryer is to be operated on LP (Liquid Propane or Butane) Gas, the dryer must be converted.
To do so, use only the approved Fisher & Paykel conversion kit listed in Accessories on page 9.
Do not use with a different gas without consulting the serving gas supplier.
The dryer must be converted for safe and proper performance by qualified service or installation
personel.
Conversion kits for Natural and LP Gas are available from your local Fisher & Paykel Dealer (see
Accessories page 9). If other conversions are required, check with your local gas utility for specific
information concerning conversion requirements.
WARNING
Explosion Hazard
Installations must be performed by a qualified or licensed
contractor, plumber, or gasfitter qualified or licensed by
the state, province, or region where this appliance is being
installed.
Use a new AGA or CSA approved gas supply line.
Install a shut-off valve in an accessible place.
Only use a gas shut-off valve approved for use within the state,
province, or region where this appliance is being installed.
Securely tighten all gas connections.
If connecting to LP Gas, have a qualified person make sure
gas pressure does not exceed 13" (33 cm) water column.
Failure to follow these instructions can result in death,
explosion, or fire.