Specifications
and Performance Claims.
This model is efficiency
rated, The efficiency
rating is valid only at the minimum
stated salt dose, The softener
has a demand
initiated
regeneration
(D,I,R)feature
that complies
with specific performance
specifications
intended to minimize
the amount
of regenerant
brine and water
used in its operation.
The softener
has a rated salt efficiency
of not less than 4,000 grains of total hardness
exchange
per pound
of salt (based on
sodium
chloride}, and shall not deliver more salt than its listed rating or be operated
at a sustained
maximum
service flow
rate greater than its listed rating.
This softener
has been proven to deliver soft water
for at least ten continuous
minutes
at
the rated service flow rate. The rated salt efficiency
is measured
by laboratory
test described
in NSF/ANSI Standard/44,
These
tests represent
the maximum
possible efficiency that the system can achieve,
Operational
efficiency
is the actual efficiency
after the system has been installed,
It is typically
less than the efficiency,
due to individual
application
factors
including
water
hardness, water
usage, and other contaminants
that reduce the softener's
capacity.
Specifications
Hodel
GXSF30V
Rated Capacity*
(Grains@ Salt Dose}
i2,OOO @ 2,5 Ibs
25,400 @ 7.9 Ibs.
30,/400 @ 13,3 Ibs,
Rated Efficiency**
(Grains/Pound
of Salt @ Minimum
Salt Dose)
/4,700 @ 2.5 Ibs.
Water used during
Regeneration
(gallons/grains}
2,8/1000
Total Water Used per Regeneration
@ Maximum
Salt Dose
35.5 gallons
Amount
of High Capacity
Ion Exchange
Resin (Ib/cu,ft.)
43/0,83
Resin Tank Nominal Size (in., dia. x height)
9 x 35
Service Flow Rate (gpm)
7.5
Pressure Drop at Rated Service Flow (psi@
8.3
Water Supply Haximum
Hardness (gpg)
95
Water Supply Maximum
Clear Water Iron (ppm)***
8
Water Pressure Limits (minimum
maximum
psi}****
20 125
Water Temperature
Limits (minimum-max.
°F)
40 120
Maximum
Flow Rate to Drain (gpm)
2.3
These systems conform
to NSF/ANSI/44 for
the specific capacity
claims as verified
and
substantiated
by test data.
*
Testing was performed
using pellet grade
sodium
chloride as the regenerant
salt.
**
Efficiency rating is valid only at the lowest
stated salt dosage, These softeners
were
efficiency
rated according
to NSF/ANSI/44,
***
Extent of iron removal may vary with
conditions.
The capacity
to reduce clear water
iron is substantiated
by WOA test data. State
of Wisconsin
requires additional
treatment
if water supply contains
greater than S ppm
clear water iron. Refer to Cleaning
Iron Out of
the Water Softening
System section.
Performance Claims
Influent
Maximum
Allowable
Contaminant
Challenge
Level
Product
Water
Level
Barium
10 _+10% mg/L
2.0 mg/L
Radium 226/228
25 pCi/L
5pCi/L
Test parameters
include:
pH - 7.5_+0.5,flow rate - 7.5 gpm
and dynamic
pressure - 35_+5 psig
Canada working pressure limits: 1.4 7,0 kg/cm£