Water Softening
System
Model GXSF30V
Write the model and serial
numbers here:
Model #
Serial #
To find these numbers, lift
the cover and look on the rim
below the control panel.
Systems tested and certified by NSF International against
NSF/ANS!Standard 44 for the chemical reduction claims
specified on page 3.
Systems Tested and Certified by the Water Quality Association
against CSAB483.1.
If you have any questions or concerns when installing or maintaining your
water softener, call our toll free number at 800-952-5039 (US)or 866-777-7627
(Canada}, or visit www.geappliances.com
When you call, please be prepared
to provide the model and serial number of your product. This information can
be found on the rating decal located on the rim under the salt cover.
7329196
49-50282-1 01-12 GE

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for GE GXSF30V

  • Page 1: Table Of Contents

    Safety Information ....Specifications &Performance Claims... System About the Softener ....Before you Start ....... Installation Requirements ..8-10 Model GXSF30V Installation Instructions ... ii-14 Programming the Softener ..15-19 Write the model and serial Care and Cleaning ....numbers here: Routine Maintenance ....
  • Page 2: Safety Information

    IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. SAFETYPRECAUTIONS _k WARNING! For y our sdety, the information inthis manual must be _ollo_ed tominimize the risk of electric shock, property damage or personal injury. A WA RNI NG:oo &DANGER: not use with water Electric Shock Hazard: that is microbiologically unsafe or of unknown...
  • Page 3 Specifications Hodel GXSF30V Rated Capacity* (Grains@ Salt Dose} i2,OOO @ 2,5 Ibs 25,400 @ 7.9 Ibs. 30,/400 @ 13,3 Ibs, Rated Efficiency** (Grains/Pound of Salt @ Minimum Salt Dose) /4,700 @ 2.5 Ibs.
  • Page 4 About the water softener system. SERVICE When the water softening system is providing After a period of time, the resin beads become soft water, it is called "Service." During service, coated with hard minerals and they have to hard water flows from the house main water pipe be cleaned.
  • Page 5 About the water softener system. NORMAL OPERATION, CONTROL DISPLAYS During normal operation, the present time of day and AM or PM and DAYS TO EMPTYshow in the control display area. The system will automatically recharge at the preset recharge time as needed. FEATURE: OPTIONAL RECHARGE...
  • Page 6 "Set Water Hardness Number" section. reduced life of the resin. In these conditions, may wish to consider purchasing a GE point-of- Ferric (red water), and bacterial and organically entry household filtration system with a chlorine bound irons are insoluble. This water softener reducing filter.
  • Page 7: Before You Start

    Before you start. BEFORE YOU START The water softener requires a minimum water flow of 3 gallons per minute at the inlet. Maximum allowable inlet water pressure is 125 psi. If daytime pressure is over 80 psi, nighttime pressure exceed the maximum. Use a pressure reducing valve if necessary...
  • Page 8: Om Installation Requirements

    Installation Requirements. DO NOT RUN HOT WATER THROUGH THE LOCATION REQUIREMENTS Consider all of the following when selecting an SOFTENER. Temperature of water passing installation location for the water softener. through the softener must be less than 120 ° F. Avoid installing in direct sunlight.
  • Page 9 Installation Requirements. PLUMBING CODES VALVE DRAIN REQUIREMENTS All plumbing must be completed in accordance Using the flexible drain hose (included) see Figure with national, state and local plumbing codes. 2, measure and cut to the length needed. Flexible drain hose is not allowed in all localities (check In the state of Massachusetts: The Commonwealth your plumbing codes).
  • Page 10 Installation Requirements. 3-VALVE BYPASS SYSTEM INLET/OUTLET PLUMBING REQUIREMENTS Always install either a single bypass valve For soft water service: Open the inlet and outlet (provided),as shown in Figure 4, or, if desired, parts valves and close the bypass valve. for a 3 valve bypass system (not included) can be For bypass hard water: Close the inlet and outlet purchased and assembled, as shown in Figure 5.
  • Page 11 Installation Instructions. TYPICAL INSTALLATION Hard Water Ground to Outside Faucets Incoming- 1" NPT Sweat Hard Water lug-in included) Transformer ,1" NPT Threaded Adaptor O-ring Controller Elbow )ass Valve Valve Hose* Figure 7 Secure Valve Drain Hose in place over Floor Drain *Do not connect the water _¢s_==£...
  • Page 12 Installation Instructions. TURN OFF WATER SUPPLY 1. Close the main water supply valve, located near Salt the well pump or water meter. 2. Open all faucets to drain all water from house Assembly pipes. NOTE: Be sure not to drain water from the water Brinewell "Nut- Ferrule...
  • Page 13: Installation Instructions

    Installation Instructions. COMPLETE INLET AND OUTLET PLUMBING WARNING! If solder is used to make pipe connection WARNING! use only lead free solder and flux to ELECTRICALSHOCK HAZARD: prevent lead poisoning. Instell metal ground clamp to metel house water supply pipe before beginning instelletion. •...
  • Page 14 Installation Instructions. TEST FOR LEAKS ADD WATER AND SALT TO THE SALT STORAGE TANK To prevent air pressure in the water softener and plumbing system, complete the following steps in order: WARNING! EXCESSIVEWEIGHT HAZARD: 1. Fully open two or more softened cold water Use two or more people to move and lift faucets close to the water softener, located salt begs.
  • Page 15 Programming the Water Softener. Salt Level I 01"-I'111-1Gollons/Min Clock I" _"" " % Remaining I"1 Days to Empty | Hardness [ I _ J_ Coil for Service | Recharge 1-1 www l_l _) Recharge Now t _'_'_'_ Tonight When the transformer is plugged into the electrical...
  • Page 16 Programming the Water Softener. SET WATER HARDNESS NUMBER SET RECHARGE (STARTING)TIME 1. Press the MODE/SET button until the arrow 1. Press the MODE/SET button until the arrow 4 points to HARDNESS. A flashing 25 will appear points to RECHARGE. in the display. Salt Level Salt Level ( Clock...
  • Page 17 Programming the Water Softener. SET SALT LEVEL DAYS TO EMPTY 1. Press the MODE/SET button until the urrow The words DAYS TO EMPTY undu number ore points to SALT LEVEL. shown in the lower hulf of the displuy. This informution is shown in the normul run displuy. This is to inform the user of the number of duys Salt Level before the suit level in the brine tunk reuches...
  • Page 18 Programming the Water Softener. OPTIONAL CONTROL SETTI NGS RESETTING TO FACTORY DEFAULT The controller display has several options and To reset the electronic controller to its factory features. default for all settings (time, hardness, etc.): 1. Press the MODE/SET button and hold until the LOW SALT ALARM display changes twice to show the flashing The LOW SALT ALARM,...
  • Page 19 Programming the Water Softener. POWER OUTAGE MEMORY LOW SALT SIGNAL If electrical power to the water softener is lost, When the DAYSTO EMPTYdrops to 15, the blue "memory" built into the timer circuitry will keep indicator light and DAYSTO EMPTYin the display oil settings for up to 24 hours.
  • Page 20: Care And Cleaning

    4 on the brinewell decal. If your water supply has clear water iron, periodic resin bed cleaning is needed. GE recommends NOTE: In humid areas, it is best to keep the salt using Super Iron Out ® brand resin bed cleaner...
  • Page 21: Routine Maintenance

    Routine Maintenance. CLEANING THE NOZZLE AND VENTURI ASSEMBLY A cleon nozzle and venturi is needed for the water softening system to work properly. This small unit makes the suction to move brine from the salt storage area to the resin tank during recharge. If it becomes plugged with sand, dirt, etc., the water softening system wilt not work and you will get hard water.
  • Page 22: Before You Call For Service

    "OUT" (service) position. • Hardness setting too low. Check hardness setting and adjust. Verify hardness of supply water- from local water company, water test or call the GE Answer Center (800-952-5039 in US). • Salt Bridge-salt solidifies above water level so that brine water is not in contact with salt.
  • Page 23 Before you call for service. Possible Cause What to do Using hot water while the water • Avoid using hot water during water softening softening system is regenerating system recharge because the water heater will refill with hard water. See Automatic Hard Water Bypass During Recharge section.
  • Page 24 Before you call for service. Possible Cause What to do Valve drain hose pinched, plugged, • A restriction in this drain hose may prevent proper elevated too high or otherwise operation of the nozzle and venturi and reduce or restricted prevent brine draw during recharge.
  • Page 25 Before you call for service. Possible Cause What to do Wiring may hove worked loose in • Unplug external power supply. the control • Remove control cover, release clips on side. • Check for loose/incorrect wiring connections to electronic board or switch. Reconnect as required.
  • Page 26 Advanced troubleshooting for service. AUTOMATIC ELECTRONIC DIAGNOSTICS Symbolsin the display indicate POSITION switch This water softener has a operation, see Figure 15 self-diagnostic function Switchis open Switchis closed ,,€ for the electrical system (exceptinto power and/ service-- I -- - Call-for or water meter).
  • Page 27 Advanced troubleshooting for service. Service: Manually Advance Recharge Check NOTE: The control display must show a steady time (not NOTE: If water system pressure is low, on elevated drain floshing). hose may cause back pressure, stopping brine draw. 1. Press the RECHARGEbutton and hold in for three Again, press the RECHARGEbutton to move the water seconds.
  • Page 28 Exploded View.
  • Page 29 Exploded View. I05_ I06_ 120/ Cross-section View...
  • Page 30 Parts List. × (oo) REF. NO. GE PART NO. PART DESCRIPTION WS]IXIO051 OO02 BACK COVER, ELECTRONICS WS]SXIO001 0003 O-RING SEAL KIT WS34XlO020 0004 DECAL, FACEPLATE WSO7XlO004 0005 HOSE, DRAIN, 20 FT. WS14XlO002 0007 DISTRIBUTOR, WS14XIO005 0008 DISTRIBUTOR, BOTTOM WSOIXIO002 0009 RESIN, 1 CU.
  • Page 31 Parts List. × REF. NO. GE PART NO. PART DESCRIPTION (oo) WSI9XIO005 Olii SUPPORT SCREEN WSO3XIO013 o112 SCREEN WS22XIO036 o113 FLOW PLUG, .15 GPM WSO8XIO008 o114 GASKET, NOZZLE/VENT WSO3XIO073 o115 SCREEN CONE WS22XIO021 o116 PLUG, FILL FLOW, .30 GPM WSO3XIO017...
  • Page 32: Warranty (U.s.)

    GE Water Softening System Warranty.IFor Customers in the U.S.) All warranty serviceprovided by our Factory ServiceCenters or an authorized technician. For service,call toll free 1-800-952-5059. Pleasehave serial number and model number available when calling for service. For The Period Of:...
  • Page 33 GE Water Softening System Warranty.(For Customers in Canada) All warranty service provided by our Factory ServiceCenters or an authorized technician.For service, call toll free 1.866.777.7627. Pleasehave serial number and model number available when calling for service. For The Period Of'.
  • Page 34 California certificate. State of California Department of Public Health Water Treatment Device Certificate Number 11 - 2107 Date Issued: September 16, 2011 '[rademark/Model Designation Rep|acelnent Elements GXSF30 3eneral ElectricCompany Manufacturer: Microbiological Contaminan:_s and Turbidity Organic (_'ontanlinallts Rated Serv ce Capac Ratcd:Serviee Flow: 7.5 9pm Conditi0ns...
  • Page 35 Notes.
  • Page 36 Notes.
  • Page 37 Informaci6n sabre Seguridad ..Especificaciones y Dimensiones ..Acerca del Suavizante ..... 40-/42 Antes de Comenzar ....Requisitos de Instalaci6n ..44-46 Instrucciones de Instalaci6n ..47-50 Programaci6n del Suavizante ..51-55 Cuidado y Limpieza ....Rutina de Mantenimiento ..... Antes de solicitar el servicio .....
  • Page 38 INFORMACION IMPORTANTE DE SEGURIDAD. LEA TODAS LAS INSTRUCCIONES ANTES DEL USO. PRECA UCIONES DE SEGURIDAD iADVERTENCIA! su seguridad, se debe seguir /a informaci6n en este manual con el fin de reducir el riesgo de una descarga eldctrica, dahos a la propiedad o dahos personales. ,IkADVERTENCIA: kPELIGRO: Descarte...
  • Page 39 Especificaciones Modelo GXSF30V Capacidad Evaluada* (Granos par Dosis de Sat) 12,000 @ 2.5 Ibs 25,400 @ 7,9 Ibs. 30,400 @ 13.3Ibs.
  • Page 40 Sobre el sistema de descalcificaci6n de aqua. SERVICIO Despu@s de un periodo de tiempo, la capa de resina se obstruye o se satura con los minerales Cuando el sistema descalcificador de agua esta duros y debe limpiarse. Esta limpieza se denomina proporcionando agua descalcificada, a esto se le recarga.
  • Page 41 Sobre el sistema de descalcificaci6n de a,qua. FUNCIONAMIENTO NORMAL, PANTALLAS DE CONTROL El sistema se recargara de forma automatica en el Durante el funcionamiento normal, la hora actual tiempo de recarga presente, seg0n sea necesario. del dia y AM o PH y DAYSTO EMPTY(DiAS HASTA VACIARSE) a parecen en el area de la pantalla de control.
  • Page 42 Una vez que el agua compra de un sistemade filtraci6n para hogar GE se asent6 par un perfodo de tiempo, las partfculas Point-Of-Entry con un filtro para la reducci6nde quedan en el fondo del envase.
  • Page 43: Antes De Comenzar

    Antes de comenzar. ANTES DE COMENZAR • El suavizante de agua requiere un flujo mfnimo de agua de ] galones por minuto en la entrada. presi6n de entrada de agua m6xima tolerable es de 125 psi. Si la presi6n del d[a supera los 80 psi, es posible que la presi6n nocturna...
  • Page 44 Requisitos de Instoloci6n. NO HAGA CORRER AGUA CALIENTEA TRAVI% REQUISITOS DE UBICACION DELSUAVIZANTELa temperatura del agua que Considere todo lo siguiente al seteccionar pasa a tray,s del suavizante deber6 ser inferior ubicaci6n de instalaci6n del suavizante de agua. a 120° F. , No coloque et suavizante de agua donde haya , Evite la instalaci6n directamente en contacto...
  • Page 45: Requisitos De Instalaci6N

    Requisitos de Instalaci6n. C6DIGOS DE PLOMERIA REQUISITOS DEL DRENAJE CON V/_LVULA Toda la plomerfa deberci ser completada de Para el uso de una manguera de drenaje flexible acuerdo con los c6digos de plomeria nacional, (incluida) yea la Figura 2, mida y corte hasta la estatal y local.
  • Page 46 Requisitos de Instalaci6n. 3-SISTEMA DE DESVIACION CON V/_LVULA REQUISITOS DE PLOMERJA INTERIOR/ EXTERIOR Para el servicio con agua suave: Abra las Siempre instale una valvula de desviaci6n simple valvulas internas y externas y cierre la valvula de (provista), coma se muestra en la Figura/4, o, si Io desviaci6n.
  • Page 47 Instrucciones de Instalaci6n. INSTALACIONTJPICA Abrazadera TubeFa de Agua con Conexi6n Agua Dura Principal Agua haciaGrifos Acondicionada I_lJ_ aTierra E×terno_ Agua Dur_ Cubierta Abrazadera con Conexi6n a Tierra Entrante Sujetadores Adaptadorde I1 l Jmranspiraci6n Transfor- I ,t_d# NPTde 1" (no _--Ensamble mador de Tuberia la V@IvuIode...
  • Page 48 Instrucciones de Instalaci6n. ClERRE EL SUMINISTRO DE AGUA 1. Cierre lav61vuladel suministro principal de aguo, ubicada Ensomble cerca de la bomba del pozo o del medidor de agua. Tape de de Boquillo la Sal 2. Abra todos los grifos pare drenar toda el ague de las tuberias de la case.
  • Page 49: Instrucciones De Instalaci6N

    Instrucciones de Instalaci6n. COMPLETE LA PLOMERIADE ENTRADAY SALIDA • AI girar los accesorios de las tuberias roscadas en los accesorios de pl6stico, tenga cuidado de no cruzar las roscas. iADVERTENCIAJ • Use Cinta de Tefl6n en todas las roscas de tuberias RIESGO DE DESCARGA ELECTRICA: externas.
  • Page 50 Instrucciones de Instalaci6n. PRUEBA DE PI_RDIDAS AGREGUE AGUA Y SAL AL TANQUE DE ALMACENAMIENTO DE SAL Para evitar la presi6n de aire en el suavizante de agua y en el sistema de plomeda, complete los siguientes pasos en orden: iADVERTENCIA! RIESGO DE PESO EXCESIVO: 1.
  • Page 51 Programaci6n del Suavizante de Agua. Salt Level I Ol'-Imnl-I Gollons/Min Clock I_ _"" " % Remaining J=_ Days to Empty | Hardness [ I _ I_ J_ Coil for Service | Recharge I-' www l"l _) Recharge Now t _'_'_'_ Tonight Cuando el transformador estci enchufado en el CONFIGURE LA HORA DEL D/A...
  • Page 52: Programaci6N Del Suavizante

    Programaci6n del Suavizante de Agua. CONFIGURE EL NUMERO DE DUREZA DEL CONFIGURACION DEL TIEMPO (INICIAL) DE AGUA RECARGA 1. Presione el bot6n MODE/SET (Modal 1. Presione el bot6n MODE/SET (Modal Configuraci6n) hasta que la flecha _ apunte a Configuraci6n) hasta que la flecha _ apunte a HARDNESS{Durezal.
  • Page 53 Programaci6n del Suavizante de Agua. D/AS HASTA VACIARSE CONFIGURE EL NIVEL DE SAL Los paJabras DAYSTO EMPTY(DJASHASTAVACIARSE) 1. Presione el bot6n IvlO,,DE/SET ( Modo/Configuraci6n) basra que la flecha • apunte a SALT LEVEL(Nivel y un nOmero se muestran en la mitad inferior de Sol}.
  • Page 54 Programaci6n del Suavizante de Agua. CONFIGURACIONES OPCIONALES DEL RECONFIGURACION A LA CONFIGURACION F/_,BRICA POR OMISION CONTROL Para reiniciar el controlador electr6nico de todas las Lo pantalla del controlador cuenta con varias opdones configuraciones al ajuste de f6brica par omisi6n (hora, y funciones.
  • Page 55 Programaci6n del Suavizante de Agua. SENAL DE NIVEL DE SAL BAJO MEMORIA POR CORTE DE CORRIENTE Cuando la funci6n DAYSTO EMPTY(Dias Hasta Si se corta la corriente del suavizante de agua, Vaciarse) cae a 15, la luz azul indicadora y DAYS la "memoria"...
  • Page 56: Cuidado Y Limpieza

    Si el suministro de agua posee hierro en el agua salmuera est@colocada. potable, es necesaria una limpieza peri6dica del fondo de resina. GE recomienda el uso de la NOTA: Si usar6 cloruro de potasio (KCI),no supere marca de limpiador de fondo de resina Super Iron el nivel 4 de la etiqueta del pozo de salmuera.
  • Page 57: Rutina De Mantenimiento

    Rutina de Mantenimiento. LIMPIEZA DEL ENSAMBLE DE LA BOQUILLA EL VENTURI Una limpieza de la boquilla y el venturi es necesaria para Tapa --_ que el sistema suavizante funcione de forma correcta. Esta peque_a unidad hace que la succi6n mueva la Sellodel anilto o ---l_'_l salmuera del 6rea de almacenamiento de sal al tanque de resina durante la recarga.
  • Page 58 Antes de solicitar el servicio t cnico. ikos Consejos pare la Soluci6n de Problemas le Permiten Ahorrar tiempo y dinero! Lea primero cuadro qua aparece en esta pdgina y es posible qua no necesite solicitar el servicio tdcnico. SUAVE - Problemas M(_s HAY AGUA Comunes: Reafice el control antes de Ilamar al servicio t4cnico:...
  • Page 59 Antes de solicitar el servicio t cnico. Causa Posible Ou_ hacer Uso de aguo coliente mientros • Evite usar agua caliente durante la recarga del sistema suavizante de agua se est6 sistema suavizante de agua, ya que el calentador regenerando de agua se volver6 a Ilenar con agua dura.
  • Page 60 Antes de solicitar el servicio t cnico. Causa Posible Qu_ hacer • Cualquier restricd6n en la monguero de drenaje La v61vula de la manguera de drenaje podr6 impedir un funcionamiento correcto de Io est6 pinzada,atascada, demasiado boquillo y el venturi y redudr o impedir el ingreso de elevodo o de alg_n modo restringida...
  • Page 61: T_Cnico

    Antes de solicitar el servicio t_cnico. Ou_ hacer • Desenchufe el suministro de corriente externo. • Retire la tapa del control, libere los sujetadores costado. • Controle que no haya conexiones de cables sueltos/ incorrectas al tablero electr6nico o interruptor. Vuelva a conectar segOn se requiera.
  • Page 62 SoluciGnde problemasavanzados para el servicio t cnico. DIAGNOSTICO ELECTRONICO AUTOM/_TICO 5. Los dmbolos en la pantalla indican el funcionamiento del interruptor de POSICION. Yea la Figura 19 Estesuavizante de agua cuenta f con una funciGn de auto Switch is open diagnGsticodel sistema el_ctrico/ Switch iLclosed (exceptopara la corriente...
  • Page 63 SoluciGn de problemasavanzadospara elserviciot cnico. Servicio: Control de Recarga Avanzado en forma Manual NOTA:Si elsistemo de presiGndel agua es bajo,una NOTA: La pantallo d e control debe mostrarelhoratio de manguera de drenaje elevado podr6 ocasionarpresiGn manera fUo(notitilando). trasera, deteniendoel ingresode salmuera. 1.
  • Page 64 Vista E×pandida.
  • Page 65 Vista E×pandida. I05_ I06_ 120/ Cross-section View...
  • Page 66 Listado de Piezas. × REF. NO. GE PART NO. PART DESCRIPTION (00) 0002 WS31XIO051 SOPORTE, PLACA 0003 WS35ZlO001 KIT DE SELLADO DE ANILLOS 0004 WS34ZlO020 CALCOMAN[A, PLACA 0005 WSO7XIO004 MANGUERA, DRENAJE, 20 PIES 0007 WS14ZIO002 DISTRIBUIDOR, SUPERIOR 0008 WS14XSO005 DISTRIBUIDOR,...
  • Page 67 Listudo de Piezus. × REF. NO. GE PART NO. PART DESCRIPTION (00) 0111 WSI9XIO005 PANTALLA DE SOPORTE 0112 WSO3XIO013 PANTALLA 0113 WS22XIO036 ENCHUEE DEL FLUJO, .15 GPM 0114 WSOSXIO008 JUNTA, BOOUILLA/VENTILACION PANTALLA CONICA 0115 WSO3XIO073 0116 WS22XIO021 ENCHUFE, FLUJO DE LLENADO, .30 GPM...
  • Page 68: Garantia (Ee.uu.)

    EE.UU. S i elproducto se encuentra en undrea dondeno se encuentra disponibleun Proveedor Autorizado de ServicioT_cnico de GE,usted serd responsablepar el costa de un viajeo se podrd requerir quetraiga elproducto a una Ubicaci6ndel Servicio T_cnicode GEAutorizado paro recibir el servicio.En Alaska,la garantfa excluye elcosta de envfo o Ilamadas del servicio a su hogar.
  • Page 69: Garantia (Canad6)

    Garantia del Sistema Suavizante de Agua de EJpara Clientes Canadd) Todo elservicio de garantfa esprovisto par nuestros Centros de Serviciode Fobricaci6n,o un tdcnico autorizado. Para solicitor el servicio tdcnico, llame al nOmero gratuito Z866. 777.7627. Cuando llame para solicitor el servicio,tenga losnOmeros de seriey modelo disponibles. Por el Periodo Reemplazaremos: Un ASo...
  • Page 70 Certificado de California. State of California Department of Public Health Water Treatment Device Certificate Number 11 - 2107 Date Issued: September 16, 2011 '[rademark/Model Designation Rep|acelnent Elements GXSF30 3eneral ElectricCompany Manufacturer: Microbiological Contaminan:_s and Turbidity Organic (_'ontanlinallts Rated Serv ce Capac Ratcd:Serviee Flow: 7.5 gpm Conditi0ns...
  • Page 71 Manuales de los Propietados o pedir piezas en linea. Solicite una reparaci6n GEAppliances.com El servicio de expertos GE est6 a tan s61oun paso de su puerta. Llame al 800.GE.CARES (800./432.2737) durante horas normales de ofidna para solidtar su reparad6n. Real Life Design Studio (Estudio de diseho para la vida real) GEAppliances.com...
  • Page 72 Contact Us GEAppliances.com If you are not satisfied with the service you receive from GE,contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations GE Appliances, Appliance Park...

Table of Contents