Section 3-3-3: Heat Shields

Installing a Wall Mounted RHS8 Heat shield
The RHS8 Heat shield CANNOT be used when the Termination is WITHIN
(36" Min. horizontal and 46" Min. vertical) from the fireplace, or directly
off the rear of the fireplace, as shown figure 19a. The RHS101 Heat
Shield (Figure 19c and 19d) MUST be used within the noted dimensions.
To install the RHS8, frame an opening in combustible construction,
Figure 19 below. Slide the Heat shield in place over the vent pipe
which attaches to the fireplace. After the fireplace and vent pipe has
been installed, clearances should match the dimensions in Figure 19.
2" Min.
Figure 19. RHS8 Installation. (Install by sliding over vent pipe
where it passes through the combustible construction).
36" Min
46" Min.
Figure 19a. RHS8 Installation. (Minimum requirements).
Page 16
Installation
1" Min. Both sides Typical
RHS8 Heat Shield
Combustible Framing
RHS8 Heat
Shield
PTO Termination
Installing a Wall Mounted RHS101 Heat shield.
The RHS101 Heat shield MUST be used where the RHS8 Termination
(Figure 19 and 19a) CANNOT be used. Use the RHS101 where any
of the dimensions are within the parameters shown, figure 19a.
To install the RHS101, Slide the Inner Section over the vent pipe that
will connect to the fireplace. Then fasten the vent pipe to the back of the
fireplace with a minimum of three sheet metal screws. (Note: ensure you
maintain the Max. 12" fireplace clearance). From the outside slide the
RHS101 outer section on see Figure 19c. To complete the installation
fasten the Heat Shield Outer Section & Termination frame to the structure
Figure 19d.
RHS101 Heat Shield
Outer Section
Termination
12" max
Figure 19c. RHS101 Installation. (Install by sliding Outer
Section over vent pipe where it passes through the
combustible construction.
RHS101 Heat Shield
Outer Section
Termination
Figure 19d. Heat Shield. After sliding the outer section in
place.
Drywall / sheetrock
RHS101 Heat Shield, inner Section
Vent pipe, from fireplace
Fireplace
Combustible
framing
Drywall / sheetrock
RHS101 Heat Shield, inner Section
Fireplace
XG0181 - 112811