Finishing Around The Fireplace; Clearances - Montigo H34VO Installation & Maintenance Manual

Outdoor residential gas fireplace
Table of Contents

Advertisement

Clearances

Top
Header
Sides
Floor
Back
Mantel
Ceiling
Mantels & Surrounds
nOTE: National Canadian Gas Association mantel test requirements
are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
fireplaces which are hot, fuel and energy efficient.
Figure 3. Non-combustible mantles and facings.
WARNING:
When this appliance is installed directly on any combustible
material other than wood flooring, it must be installed on a
metal or wood panel extending the full width and depth of
the appliance.
XG0150 - 081711
Installation
H34VO
H(L)38VO
H42VO
With
With
Insulation
Insulation
Insulation
Jacket
Jacket
Jacket
9"
9"
5½"
5½"
1"
1"
0"
0"
1"
1"
12"
12"
36"
36"
Non combustible
facing
Combustible
Header @ 5½"
Top of Fireplace

Finishing Around the Fireplace

all fireplace facing must be non-combustible. Non-combustible
mantels and mouldings may be safely installed over the top and on the
With
front of the fireplace provided that they do not project beyond shaded area
shown in Figure 3. Side wall clearances are 3". Only non-combustible
9"
surrounds may be installed around and on the facing of the fireplace
as shown in Figure 3b.
5½"
1"
0"
1"
12"
36"
Figure 3a. Non-combustible facing Material
Fireplace Facing
When selecting the finish material for your fireplace, it is important to
remember the following: THE LOwER GaS COnTROL PanEL MUST
nOT BE OBSTRUCTED In anY waY - to do so restricts the air supply
for the control compartments and heat exchanger it also prevents
access for servicing controls.
Decorative facing must not extend past the fireplace opening at all,
because it will interfere with the access to retainers for removal of
glass door.
Figure 3b. Non-combustible surrounds and sidewall clearances.
H-Series VO Outdoor Gas Fireplace
* Shaded area must be non-combustible.
Either Montigo supplied nailing flange, and
cement board or other equivalent
non-combustible material.
5½"