DANGER
Read and understand this manual. Improper installation, adjustment, alteration,
service or maintenance can cause serious injury, property damage or even death.
For assistance or additional information consult a qualified installer, service
agency or the gas supplier.
DANGER
Blank
IF YOU SMELL GAS
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not try to light any appliance.
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not touch any electrical switch; do not use any phone in your building.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Flammable materials
Explosion risk
Immediately call your gas supplier from a neighbor's phone. Follow the gas
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Hot surface
Danger of entrapment
Danger of death
General Warning
Laser Radiation
Biohazard
Oxidising
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Blank
supplier's instructions.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Flammable materials
Explosion risk
falling objects
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
If you cannot reach your gas supplier, call the fire department.
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
falling objects
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
WARNING
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which has
no odor. Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space such as a
camper, tent, car or home.
C
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
XG0702
®
US
WARNING
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of
this or any other gas burning appliance. A fire or explosion my occur causing serious
injury, property damage or even death.
NOTICE
Installer: Leave this manual with the appliance. Do not remove.
Consumer: Retain this manual for maintenance and future reference. Do not Discard.
NOTICE
Installation and repairs should be done by an authorized gas fireplace service technician.
The appliance should be inspected before use and at least annually by a professional. More
frequent cleaning may be required due to excessive lint from carpeting, bedding material,
etc. It is imperative that control compartments, burners and circulating air passageways of
the fireplace are kept clean.
WARNING
FOR OUTDOOR USE ONLY.
Firepit Manual
CFPO-2 CFPO-3
CFPO-4 CFPO-5
CFPO-6 CFPO-7
CFPO-8 CFPO-9
CFPO-10
Not for use with solid fuel.
092711

Advertisement

Table of Contents
loading

Summary of Contents for Montigo CFPO-3

  • Page 1 Using it in an enclosed space can kill you. Never use this appliance in an enclosed space such as a camper, tent, car or home. FOR OUTDOOR USE ONLY. ® Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248 XG0702 092711...
  • Page 2: Table Of Contents

    Custom C-View Fireplace NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for future reference and maintenance. Table of Contents Introduction ..................3 Installation ..................4 Section 1: General Information ..........4 Section 2: Unit Specifications ............4 Section 3: Installation Location ..........5 Clearances to Surrounding Construction ........5...
  • Page 3: Introduction

    Congratulations on your purchase of a Montigo Firepit. Warranty and Installation Information (aee Appendix A) With over 30 years of experience, Montigo is committed to provid- The Montigo warranty will be voided by, and Montigo disclaims ing you with a gas appliance that is not only a beautiful addition...
  • Page 4: Installation

    Firepits have an open flame that can cause injury. Consider the safety of children and other indi- viduals during placement • Montigo requires that all framing in direct contact with the unit be of non-combustible construction • Ensure that access is available to make gas and electrical connections and for future service. We recommend using the Fresh Air Supply Grille for this access.
  • Page 5: Section 3: Installation Location

    10 square feet of fresh air per 20,000 BTU Should you be installing the firepit in a covered of your unit. Also you must install a Montigo interlocking area, you must abide by the following requirements. carbon monoxide detector in the furthest location from the opening.
  • Page 6: Section 4: Unit Dimensions

    C-View Custom Fireplace Installation Section 4: Unit Dimensions Model CFPO-2 23.5" 11.88" 24.125" 28" 12" 15.88" 12" 0.625" CFPO-3 35.5" 11.88" 36.125" 40" 12" 15.88" 12" 0.625" CFPO-4 47.5" 11.88" 48.125" 52" 12" 15.88" 12" 0.625" CFPO-5 59.5" 11.88" 60.125"...
  • Page 7: Section 6: Combustion Air Supply

    The size of this grille must meet the requirements laid out in the table below. This grille should also act as access to the gas connection shut-off valve. Model Size of Grille (sq in.) CFPO-2 3.33 CFPO-3 6.66 CFPO-4 10.00 CFPO-5 13.33 CFPO-6 16.67...
  • Page 8: Section 7: Electrical Control Panel

    C-View Custom Fireplace Installation Section 7: Electrical Control Panel This control panel will be used for units with 1 gas valve including: CFPO-2, CFPO-3, CFPO-4, CFPO-5, CFPO-6, CFPO-7, CFPO-8 MCP1-FIREPIT Electrical Control Panel for Custom Firepit SPECIFICATIONS Enclosure Material: Weathertight PVC...
  • Page 9 Valve 2 Brown Green 6.375 4.625 7.875 Fig 11: Control Panel Schematics (2 valves) Replacement Parts available from your local Montigo dealer INVENTORY QTY. Part No. Description EC1142 Transformer, Class 2 - Input: 110VAC 60Hz - Output: 24VAC 1.875A 40VA EC2046...
  • Page 10: Section 8: Electrical Connections

    C-View Custom Fireplace Installation Section 8: Electrical Connections Installing the Control Panel MCP1-FIREPIT The control panel should be installed in a location that is accessible for start up and future service. The inverter may sometimes produce a whining sound, this should be considered when selecting the panel location. Should the noise from the panel be a concern, we recommend that the box containing the panel be lined with a sound proofing material.
  • Page 11: Section 9: Installing The Gas Line

    Custom C-View Fireplace Installation Section 9: Installing the Gas Line The gas connection is located on the underside of the firepit body. The manufacturer requires a service shut off valve lo- cated in an accessible location to isolate the fireplace’s gas supply. We reccommend placing this behind your intake grate for easy access.The gas line must be installed, and tested for leaks before finishing the Custom Firepit.
  • Page 12: Section 10: Installing The Burner Accessories

    Installation Section 10: Installing the Burner Accessories Installing the Firestones The Montigo Custom Firepit with Concealed Burner is supplied with firestone glass media. Place the firestones randomly across the pan and the burners as described in Figure 14 to 14d.
  • Page 13: Operation

    1. The firepit control panel comes pre-wired to the fireplace and all internal components. If the cables that connect the panel to the fireplace need to be disconnected in order to be run inside of a conduit or raceway, follow the attached schematic to re-connect the wiring.
  • Page 14: Maintenance

    C-View Custom Fireplace Maintenance Section 12: General Maintenance and Cleaning Annual Inspection Checklist 1. Inspect the operation of the flame safety system (Honeywell HSI, flame rod, and ground electrode). 2. Inspect and ensure the lighting of the main burner occurs within 4 seconds of the main gas valve opening. Inspect primary air openings for blockage.
  • Page 15: Section 13: Troubleshooting

    Custom C-View Fireplace Maintenance C-VIEW Sequence of Operation Section 13: Troubleshooting Power up the Montigo control panel • Blown fuse Inverter displays and power indicator light up • Incorrect supply voltage Turn wall switch on • Combustion air relay on •...
  • Page 16: Appendix

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 17: Appendix B - State Of Massachusetts

    Custom C-View Fireplace Appendix Appendix B - State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by adding the following additional requirements:...
  • Page 18 CFPO Custom Outdoor Firepit Ferndale, Washington Langley, British Columbia TF: 1.800.789.6236 TF: 1.800.378.3115 FX: 1.866.3000.0927 FX: 1.604.607.6462 XG702 - 092711...