Montigo CabanaFire PL42VO Installation & Maintenance Manual

Montigo CabanaFire PL42VO Installation & Maintenance Manual

28,000 btu/hr natural gas or lp gas
Hide thumbs Also See for CabanaFire PL42VO:
Table of Contents

Advertisement

Quick Links

DANGER
CARBON MONOXIDE HAZARD
This appliance can produce carbon
monoxide, which has no odor.
Using it in an enclosed space can
kill you.
Never use this appliance in an
enclosed space such as a camper,
tent, car or home.
Page 1
Installation & Maintenance Manual
CabanaFire PL42VO
Outdoor Gas Fireplace
28,000 btu/hr Natural Gas or LP Gas
• The installation of this fireplace must be done by a qualified and
®
• Check local codes and read all instructions prior to installation.
• Installer: leave this manual with the appliance.
C
US
• Consumer: retain this manual for future reference.
certified gas appliance installer.
WARNING: For Outdoor Use Only.
WARNING: If the information in these instructions is not followed
exactly, a fire or explosion may result causing property damage,
personal injury or loss of life.
• For outdoor use only
• Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
• Do not touch glass until cooled.
• Do not allow children to touch glass.
• What To Do If You Smell Gas:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone
in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
• Installation and service must be performed by a qualified installer,
service agency or the gas supplier.
XG0219 - 160819

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CabanaFire PL42VO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Montigo CabanaFire PL42VO

  • Page 1 Installation & Maintenance Manual CabanaFire PL42VO Outdoor Gas Fireplace 28,000 btu/hr Natural Gas or LP Gas • The installation of this fireplace must be done by a qualified and certified gas appliance installer. ® • Check local codes and read all instructions prior to installation. • Installer: leave this manual with the appliance. • Consumer: retain this manual for future reference. DANGER CARBON MONOXIDE HAZARD WARNING: For Outdoor Use Only. This appliance can produce carbon monoxide, which has no odor. Using it in an enclosed space can kill you. WARNING: If the information in these instructions is not followed Never use this appliance in an exactly, a fire or explosion may result causing property damage, enclosed space such as a camper, personal injury or loss of life.
  • Page 2: Table Of Contents

    General Information & Safety Contents Conditions and Limitations ......................3 Startup and initial operation ......................25 Getting Started ..........................4 LED Operation Verification – Applicable if light kit (MCLEDVO) is installed ....25 Gas line and connection: ..................... 4 Initial Fireplace Operation Verification – If gas supply is connected .......25 Electrical: ..........................4 Initial Fireplace Operation Verification – If gas supply not yet connected ......25 Safe Operating Practices ......................5 Optimizing the Fan Speed ....................25 Certification ..........................6 Operating the Fireplace ......................26 Rating Plate Location: ......................6 Remote ............................28 Expanded Rating Plate Location: ..................6 Receiver ..........................28 Appliance Certification ........................ 7 Installation .........................28 Certification .........................
  • Page 3: Conditions And Limitations

    General Information & Safety Montigo products are designed with superior components and materials, and are assembled by trained craftsmen who take great pride in their work. Every component has been thoroughly inspected by a qualified technician before packaging and shipping to ensure that you, the customer, receive the quality product you expect from Montigo.
  • Page 4: Getting Started

    Electrical: Montigo PL42VO • The Montigo PL42VO has built in fans to force out all of the heat right above the glass window. Due to the glass window, this model is less This product should be installed by a qualified installer.
  • Page 5: Safe Operating Practices

    General Information & Safety Safe Operating Practices • If contacted this appliance can cause severe burns. • Cylinders must be stored outdoors in a well-ventilated area out of reach of children. Disconnected cylinders must have threaded valve plugs • Installation and repair should be done by a qualified service person. tightly installed and must not be stored in a building, garage or any The appliance should be inspected before use and at least annually other enclosed area.
  • Page 6: Certification

    General Information & Safety Certification Rating Plate Location: The rating plate can be found on the underside of the control box cover. Figure 2 Control box rating plate Expanded Rating Plate Location: A rating plate with additional information can be found secured with velcro on the inside wall of the base of the firebox. To access the rating plate, the door and lower air baffle must first be removed.
  • Page 7: Appliance Certification

    4500 ft. (1370m) above sea level. For installations beyond this level, please and replace any part of the control system and any gas control, which contact your Montigo dealer for high altitude conversion kits. has been underwater. XG0219 - 160819...
  • Page 8: Dimensions

    Installation Dimensions PL42VO Dimensions The PL42VO fireplace may be 43 3/4" 1111 installed in any location that 41 5/8" maintains proper clearances to 1056 39 3/4" air conditioning ducts, electrical 1011 wiring and plumbing. Safety, as well as efficiency of operation, should be considered when 11 5/8"...
  • Page 9: Location Considerations

    Figure 8 Page 9 Page 9 must be installed to with proper drainage. Montigo encourages you to consult your Building Envelope Engineer or Waterproofing Consultant for further recommendations. Within a partial enclosure which includes an overhead cover and no more than two sidewalls.
  • Page 10: Exploded Part View

    Installation Exploded Part View SCREEN MAIN ASSY WINDOW BURNER TRAY LED ASSY VACUUM TUBING ASSY BURNER ASSY VACUUM SWITCH FANS P42 Vent Free - OD ASSY NAME DATE DIMENSIONS ARE IN INCHES Tools and Supplies required TOLERANCES: 19/07/2016 DRAWN BY FRACTIONAL 1/32" TWO PLACE DECIMAL .015"...
  • Page 11: Gas Supply Requirements

    GFCI protected plug to plugin the control box is required within 3 feet of WINDOW the control box. Montigo requires a service shut off valve be located in an accessible BURNER TRAY location to isolate the gas supply. Electrical Requirement for Control Box: 120VAC, 60 Hz, 5 A. GFCI protected plug required.
  • Page 12: Framing

    Installation Framing In The Wall Installation Frame in the enclosure for the unit with framing materials. The framed opening for the assembled fireplace is 42’’ wide, x 27 1/2’’ high. 49" 32.500 14 3/4" 42" NOTE: When constructing 27.500 49" the framed opening, please 52"...
  • Page 13: Clearances

    Installation Clearances Non-combustible mantels and mouldings may be safely installed over NOTE: National Canadian Gas Association mantel test requirements are the top and on the front of the fireplace provided that they do not project for fire hazard prevention to combustible materials. beyond shaded area shown.
  • Page 14: Finishing

    Installation Finishing Standalone WALL BOARD/FINISHING MTL FRAMING P42VFO FIREPLACE Fireplace Facing 12" When sizing the finish material for your fireplace, it is important NAME DATE DIMENSIONS ARE IN INCHES TOLERANCES: 15-Aug-16 DRAWN BY FRACTIONAL 1/32" to remember the following: TWO PLACE DECIMAL .015"...
  • Page 15: Mounting The Fireplace Control Box

    Installation Control Box Install Mounting the Fireplace Control Box Wiring Install the Fireplace Control Box in an accessible location. The location A qualified electrician must install the wiring.The PL42VO supplied should be where maintenance, adjustments and service may be made with an external electrical control box pre-wired by the factory. The easily.
  • Page 16 Installation Wiring Connection Control Box 24VDC Speed control Black Fast/Slow Brown SUPPLY CONTROLLER 110V White Black R G B On/Off Brown Plug Blue Remote Multiple Connection Options Gas Valve Flue Gas Combustion LED Lighting Fireplace 120VAC Fireplace Blowers 3 foot Power Cord to control box White Yellow...
  • Page 17: Wiring Instructions

    Installation Remote Receiver Installation (Optional Accessory) Wiring Instructions A qualified electrician should install the remote control system. Turn off all power and gas to fireplace. NOTE: the control box is supplied with 3 feet of 3 conductor cable. This remote control system must be installed exactly as outlined in these instructions.
  • Page 18: Wiring Instructions

    Installation LED Remote Receiver Installation (Optional Accessory) Wiring Instructions A qualified electrician should install the remote control system. Turn off all power and gas to fireplace. This remote control system must be installed exactly as outlined in these instructions. Read all instructions completely before attempting installation. Follow instructions carefully during installation.
  • Page 19: Led Strip Instructions

    Installation LED Strip Installation (Optional Accessory) LED Strip Instructions Power to the unit must be disconnected before installing For instructions on how to remove the door please see the door install/removal section. Figure 43 Removing air baffle 4. Loosen the 3 bolts securing the baffle to the back of the firebox. Figure 44 Figure 40 Removing air baffle...
  • Page 20: Gas Connection

    FUEL CONVERSION GAS CONNECTION • Verify that your fireplace is compatible with your available gas type. • Cabanafire PL42VO fireplace is supplied with a 1/2 FPT gas shutoff (Natural Gas or Propane shown by "N" or "L" in your model number valve and rating plate.
  • Page 21: Installing & Removing The Door

    Installation Installing & Removing the Door Removing the door The CabanaFire PL42VO* doors are removed in a few simple steps. Follow these instructions below. Step 4: Pull the door forward to complete the removal of the door. Step 1: Remove the inner screw on the lower left side below the door.
  • Page 22: Installing The Firestones

    WARNING: This appliance is intended for use only with the included Montigo burners and accessories. Never install or add any additional or alternative media, rock wool or other material in this appliance. The use of additional or alternative materials may pose potential safety hazards, damage to the appliance, and void manufacturer’s warranty.
  • Page 23: Installing Optional Media

    Figure 59. WARNING: This appliance is intended for use only with the included Montigo burners and accessories. Never install or add any additional or alternative media, rock wool or other material in this appliance. The use of additional or alternative materials may pose potential safety hazards, damage to the appliance, and void manufacturer’s warranty.
  • Page 24: Installing Optional Media

    Installation Installing Optional Media Step 5. Place Log 4 at the rear of the firebox, parallel to the media tray. Step 3. Place Log 3 resting diagonally against log 5, with the thinner end pointing into the top left corner of the firebox. See Figure 60. See Figure 59.
  • Page 25: Startup And Initial Operation

    Operation Startup and initial operation Initial Fireplace Operation Verification – LED Operation Verification – If gas supply not yet connected Applicable if light kit (MCLEDVO) is installed • Check that the door glass is clean. Clean if required. • Install 2 AAA batteries into LED remote • Check that the visible surfaces inside the fireplace and on the door • Turn on main power to fireplace control box frame are free of smudges.
  • Page 26: Operating The Fireplace

    If the fireplace will not light, turn the fireplace off, turn off all the electrical power to the appliance, locate the gas shut off valve and turn the gas off. Call your service technician or local Montigo dealer. Never attempt to light the pilot by hand.
  • Page 27: Lighting Instructions

    "To Turn Off Gas To Appliance" and call your service 4. Turn the fireplace "ON" using the wall switch or remote technician or Montigo dealer. control. NOTE: This unit is equipped with an ignition system that lights the pilot burner automatically.
  • Page 28: Remote

    SETTING C SCALE INSTALLATION AN IF YOU CANNOT READ OR UNDE Operation ATTEM The factory setting hold the ON butto INTRODUCTION for (5) seconds. F This SKYTECH remote control system was developed to p Remote heating appliances. The system can be operated manuall a 20-foot range using non-directional signals.
  • Page 29: General Information

    Operation Remote General Information System Check The system can be operated manually from the receiver using the slider • Slide the 3-position button on the remote receiver to the ON position. switch. The fireplace will go through the start cycle and the hot surface igniter will glow after the pre purge time and ignite the pilot.
  • Page 30: Remote Layout

    ATTEMPT TO INSTALL OR OPERATE INTRODUCTION This SKYTECH remote control system was developed to provide a safe, reliable, and user-frie Operation heating appliances. The system can be operated manually from the transmitter. The system a 20-foot range using non-directional signals. The system operates one of 1,048,576 security transmitter at the factory;...
  • Page 31: Changing The Temperature Scale

    SETTING C SCALE Operation Remote Changing the Temperature Scale: Changing the Childproof Lock: The factory temperature setting is Fahrenheit. The remote control includes a childproof lock-out feature. To change the setting to Celsius, simultaneously press and hold the ON To activate the childproof lock, simultaneously press and hold the ON and button and FLAME ICON on the LCD screen for five seconds.
  • Page 32: Battery Life

    Operation Remote Battery Life Troubleshooting Life expectancy of the alkaline batteries in the transmitter should be at If you encounter problems with your fireplace system, the problem may be least 12 months. with the fireplace itself or it could be with the remote control. Review the fireplace manual to make sure all connections are properly made.
  • Page 33: Led Remote Control Operation

    Operation LED Remote Control Operation This system is a high-performance RGB LED touch remote controller, Speed Brightness adopting the most advanced PWM control technology, controlling Mode state state all RGB LED products with Five lines and three circuits( common anode),owning 640 thousand colors and 12 automatic changing modes Static white color Adjustable Unadjustable...
  • Page 34: Installing & Removing The Screen

    Maintenance Installing & Removing the Screen Note: Do not operate fireplace without all screens in place. Step 1: Step 3: Remove the door/screen Pull the screen upwards to from the firebox ( see door remove it from the door. removal instructions on previous page ) Figure 80 Figure 78 Replacement Screens:...
  • Page 35: Troubleshooting Guide

    If your fireplace still does not operate correctly, consult your local Montigo dealer. All service and repairs should be performed by a qualified Technician. All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer. XG0219 - 160819...
  • Page 36: Maintenance / Cleaning Instructions

    If any of these conditions exist, do not use the appliance. available from your local montigo authorized dealer/distributor. Have the part replaced by your Montigo dealer or qualified gas WARNING! To avoid the possibility of burns, maintenance should be installer.
  • Page 37: Appendix A: Warranty

    On obligation, and purchaser's exclusive remedy under this Warranty, the Montigo fireplace, there is a ten-year warranty on the firebox and under any other warranty, expressed or implied, or in contract, tort...
  • Page 38: Amendment

    Appendix Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as 4. INSPECTION. The state or local gas inspector of the side wall follows: horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon...
  • Page 39: Xg0219

    Notes XG0219 - 160819 Page 39...
  • Page 40 PL42VO Ventless Outdoor Fireplace XG0219 - 160819...

Table of Contents