Note: Barometric air pressure is usually reported as "relative air
pressure". This reading is based on the combination of absolute air
pressure and altitude. In general, an increase in altitude will result in a
decrease in air pressure. Relative air pressure will make readings in
nearby locations relative to each other to allow for proper forecasting.
The absolute air pressure reading in the Weather Center cannot be
calibrated, only the relative air pressure.
6. Press and release the "SET" button to confirm the forecast sensi-
tivity setting.
THE MANUAL SETTING IS NOW COMPLETED
FEATURES AND OPERATIONS
A. Minimum and Maximum Temperature and Humidity
1. Indoor Minimum and Maximum Temperature and Humidity
The indoor weather station automatically stores the minimum and
maximum indoor temperature and humidity. The minimum and maxi-
mum values are updated automatically when a new minimum or maxi-
mum is recorded, or until manually reset.
a. From the normal display mode, press and release the "IN" key once
to view the indoor maximum temperature and humidity ("MAX" will
be displayed above the indoor temperature and humidity).
b. Press and release the "IN" key again to view the indoor minimum
temperature and humidity.
c. Press and release the "IN" key again to return to the normal mode
(timeout of viewing minimum/maximum values will occur if no keys
are pressed for fifteen seconds).
Note: To reset the indoor minimum and maximum temperature and
humidity, first display the values you wish to reset (minimum or
maximum). Next press and hold the "SET" key for at least three
seconds. You will see then that the values will reset to the current
temperature and humidity and corresponding time.
2. Outdoor Minimum and Maximum Temperature
The indoor weather station automatically stores the minimum and
maximum outdoor temperature. The minimum and maximum values
are updated automatically when a new minimum or maximum is
recorded, or until manually reset.
a. From the normal display mode, press and release the "OUT/+" key
GB
P.16
once to view the outdoor maximum temperature ("MAX" will be dis-
played above the outdoor temperature).
b. Press and release the "OUT/+" key again to view the outdoor mini-
mum temperature.
c. Press and release the "OUT/+" key again to return to the normal
mode (timeout of viewing minimum/maximum values will occur if
no keys are pressed for fifteen seconds).
Note: To reset the outdoor minimum and maximum temperature, first
display the values you wish to reset (minimum or maximum). Next
press and hold the "SET" key for at least three seconds. You will see
then that the values will reset to the current temperature and corre-
sponding time.
B. Multiple Remote Temperature Sensors
The WS-7394U-IT is able to receive signals from 2 additional tem-
perature sensors. The following are instructions for the set-up of tem-
perature sensor units with the WS-7394U-IT. These extra sensors can
be purchased through the same dealer as this unit.
1. Remove all the batteries from the receiver and sensor(s) and wait
60 seconds. During these 60 seconds, press any button 20 times
to discharge any excess power.
2. Insert the batteries to the first temperature sensor.
3. Within 2 minutes of powering up the first sensor, insert the batter-
ies to the Weather Station. Once the batteries are in place, all seg-
ments of the LCD will light up briefly. Following the indoor tempera-
ture and humidity, and the time as 12:00 will be displayed. If they
are not shown in LCD after 60 seconds, remove the batteries and
wait for at least 60 seconds before reinserting them.
4. The outdoor temperature from the first sensor (channel 1) should
then be displayed on the Weather Station. If this does not happen
and the signal reception icon is not shown, after 2 minutes, the
batteries will need to be removed from both units and reset from
step 1.
5. Insert the batteries to the second sensor as soon as the outdoor
temperature readings from the first sensor are displayed on the
Weather Station.
NOTE: You must insert the batteries into the second sensor within 10
seconds of reception of the first sensor.
6. The outdoor temperature from the second sensor and the "channel
2" icon should then be displayed on the Weather Station. If this
does not happen after 2 minute, the batteries will need to be re-
moved from all the units and reset from step 1.