Unit 4: Standard Command Codes
FORM OVERLAY, RECALL
FUNCTION
To recall the label image from the form overlay memory for printing. Additional or
different data can be printed with the recalled image.
FORMAT
<ESC>/
Must be preceded by all other data and placed just before Print Quantity (<ESC>Q)
command.
EXAMPLE
<ESC>A
<ESC>H01000<ESC>V0125
<ESC>STHIS IS THE STORED IMAGE WITH A BARCODE
<ESC>H0100<ESC>V0165<ESC>B103100*12345*
<ESC>&<ESC>Z
<ESC>A<ESC>H0100<ESC>V0050
<ESC>STHIS IS RECALLING AND ADDING TO THE STORED IMAGE<ESC>/
<ESC>Q1
<ESC>Z
OUTPUT
(4-11)
NOTES
The overlay is stored using the Form Overlay Store (<ESC>&) command.
If this command is used with the Expanded Print Length (<ESC>EX0) command the
Form Overlay length cannot exceed 9999 dots.
Refer to Appendix: Reference Table 8 for additional information.