Horizontal Term. With Three Vert. Elbows - FireplaceXtrordinair 44 DV XXL EF Manual

Built-in direct vent fireplace
Hide thumbs Also See for 44 DV XXL EF:
Table of Contents

Advertisement

Horizontal Terminations with Three Vertical Elbows
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor position.
Travis Industries
Installation
NOTE:
• A total of three elbows must be used.
• No horizontal elbows may be used (a horizontal elbow is defined
as an elbow that directs the vent from a horizontal direction to
another horizontal direction).
• Two 45° elbows may be substituted for two of the 90° elbows.
• Horizontal sections require a 1/4" rise every 12" of travel.
• The maximum vertical height is 19'.
• The maximum horizontal length is 20'.
Horizontal Elbows are
NOT ALLOWED
19' (max)
NOTE:
Restrictor positions are based upon
lab tests. The ideal restrictor position
may vary slightly.
15 feet
10 feet
5 feet
0 feet
(for qualified installers only)
Restrictor
Position #5
Restrictor
Position #1
Min. 24" Rise
Before First Elbow
4050114
19' (max)
15 feet
10 feet
5 feet
0 feet