Installing An Optional Serveraid Upgrade Adapter - IBM System x3650 M4 Type 7915 Installation And User Manual

Type 7915
Hide thumbs Also See for System x3650 M4 Type 7915:
Table of Contents

Advertisement

To install any of the four replaceable fans, complete the following steps:
1. Read the safety information that begins on page vii and "Installation guidelines"
2. If you have not done so already, slide the server out of the rack and remove the
3. Rotate the air baffle up.
4. Orient the new fan over its position in the fan bracket so that the connector on
5. Align the vertical tabs on the fan with the slots on the fan cage bracket.
6. Push the new fan into the fan connector on the system board. Press down on
If you have other devices to install or remove, do so now. Otherwise, go to
"Completing the installation" on page 135.

Installing an optional ServeRAID upgrade adapter

To install an optional ServeRAID adapter upgrade adapter, complete the following
steps:
1. Read the safety information that begins on page vii and "Installation guidelines"
2. Turn off the server and peripheral devices and disconnect all power cords and
3. Remove the cover (see "Removing the cover" on page 54).
4. Connect the supercap cable to the ServeRAID upgrade adapter.
Vertical tabs
Fan 4
Fan 3
Fan 2
on page 40.
cover (see "Removing the cover" on page 54).
Attention:
To ensure proper system cooling, do not remove the top cover for
more than 30 minutes during this procedure.
the bottom aligns with the fan connector on the system board.
the top surface of the fan to seat the fan fully. Make sure that the yellow LED
next to the fan connector on the system board is off.
on page 40.
external cables (see "Turning off the server" on page 28).
Fan 1
Chapter 2. Installing optional devices
125

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents