Indication For Use; General Information - Field Controls 46448400 Manual

Air purifying system
Table of Contents

Advertisement

I.

INDICATION FOR USE

This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for
use in the mitigation, treatment, or prevention of any disease or condition.
II.

GENERAL INFORMATION

Model
Volts
UV-1500C
120
WARNING: This product is designed for indoor installation only.
The UV-1500C is designed as a multipurpose room air purification system. The unit can be placed in a room sitting on
the floor, it can be mounted on the wall to maximize floor space or it can be mounted into a suspension (drop) ceiling.
F
EATURES
1. The UV-1500C is equipped with a speed control to allow the user to adjust the airflow through the unit from 35
cfm to 100 cfm.
2. The UV-1500C has a safety shut off switch that disconnects power to the fan and the lamp if the front access
door is opened.
3. The UV-1500C is equipped with a circuit board to monitor the operation of the UV lamp; it indicates the
operation of the lamp through a LED indicator light mounted on the front access door. The circuit board
indicates good operation of the lamp by a continuous "GREEN" color on the LED light. After 8320 hrs of lamp
operation, the circuit board indicates the elapsed time of lamp operation by a continuous "YELLOW" color on
the LED light and the internal alarm will beep every 15 minutes. After 9000 hrs of lamp operation, the circuit
board indicates the elapsed time of lamp operation by a continuous "RED" color on the LED light and the
internal alarm will beep every 5 minutes. The board also checks if the UV lamp is burned out. The circuit
board will indicate this by a continuous "RED" color on the LED and the internal alarm will beep every 5
minutes.
III.
UV-1500C CHECK OUT PROCEDURE
1.
Plug the power cord into a standard 120-volt wall receptacle.
2.
Turn the speed control knob clockwise to turn the unit on. After the fan has started, the LED light will show a
continuous "GREEN" color indicating proper unit operation.
3.
Once you have determined that the unit is functioning properly, turn unit off and unplug.
4.
Continue to next section for mounting options.
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or
blindness. Never operate the UV-Aire™ Air Purifying System with the UV chamber door open. Avoid touching the glass portion of the
lamp with your hands.
Lamp Intensity
Amps
Watts
Hz
at 1 meter
37 μW/cm
1.3
60
130
Recommended
Weight
Max Sq. Feet
2
1500
15.5 Lbs
Page 2
Width
Height
Depth
(Inches)
(Inches)
(Inches)
18
23-3/4
6-5/16