The part of control panel seat
1)Method of opening the control panel
A.Open the back cover. Loosen the locking belt fixed on the cabinet (used
in inner wiring), to loosen the inner wiring.
B.Loosen the four screws used to install the control panel seat (rear and side).
Lift the rear upwards. Loosen the control panel seat from the inlay of the
cabinet. Then move it forwards several times. Turn the control panel seat
backwards to open it gently. Do not open by force.
Attention:
Do not lift the control panel seat by force, otherwise the safety switch
control rod may get transformed, and the jointer part of the connecting pipe
of the water level sensor may be loosened, therefore influence the normal
operation of the microswitch and water level sensor.
After opening the control panel seat, hold it with one hand or lean it on
supporter like the wall. Do not put it down.
2)Points of attention in assembly
Fix the wiring in the control panel seat to its original position. Do not make it
touch sharp corner and mobile position. The space surrounding the
computer
sequencer is rather narrow. Please dispose it carefully and do not make the
transformer press the wires.
Confirm that the control panel seat is installed to proper position of the
cabinet. Pay attention on the adjusting of the gap between the control panel
seat and the cabinet.
The cabinet and outer tub component
1) Method of disassembling
A.Loosen the two motor bolt unit to dismantle the motor. To adjust the tension
of
the belt, loosen the bolts and move the motor left and right.
B.Loosen the four fastening screws to dismantle the delivery shield.
C.Loosen the two fastening bolts to dismantle the drain motor.
D.In dismantling the drain valve, first loosen the screws, then rotate
combination part with the drain hose, overflow hose and outer tub slowly to
make it loose. Then dismantle the drain valve.
E.In dismantling the inner tub, first take off the outer tub cover, then dismantle
the pulsator, finally dismantle the inner tub. Handle with care when taking
the inner tub off from the outer tub.
2) Points of attention in assembly
In installation of the drain valve, please smear a piece of 801 glue at the
connection part between the drain valve and outer tub and between the
overflow hose and drain hose to guarantee that the drain valve will not leak.
In fastening the screws, make it tight without sliding.
Take care not to scratch the cabinet and influence the appearance of the
Machine.