Closed with Code Change Defects in Fabric OS v7.0.1
Defect ID: DEFECT000364945
Summary: Unable create 4th tunnel with crossport circuits in chassis with multiple FX8-24 blades.
Symptom: Unable create more than three tunnels with crossport circuit configuration in a chassis with
multiple FX8-24 blades.
Feature: FCIP
Probability: High
Found in Release: FOS7.0.0
Defect ID: DEFECT000365069
Summary: ICL Ports on 8510 directors show "Mod_Val" on 1 out of 4 ports on a QSFP.
Symptom: Event log indicates bad QSFP requiring reseat or replacement.
Workaround: Reseating QSFP may correct the issue
Feature: 16G Hardware
Probability: Low
Found in Release: FOS7.0.0
Defect ID: DEFECT000365071
Summary: QSFP port status is not refreshed in WebTools port admin window.
Symptom: Insertion/Removal of QSFP is not reflected in Port Admin window.
Workaround: Refresh, or close and re-open Port Admin window
Feature: WebMgmt
Probability: Medium
Found in Release: FOS7.0.0
Defect ID: DEFECT000365075
Summary: QSFP ICL ports are being fenced due to excessive state changes even though current high
threshold value is not exceeded
Symptom: QSFP ICL links are getting fenced unexpectedly.
Feature: FABRIC WATCH
Probability: Low
Found in Release: FOS7.0.0
Defect ID: DEFECT000368931
Summary: Deprecate FruReplace CLI command in FOS
Symptom: Use of FruReplace command in the process of performing replacement of a defective WWN
card will result with a potential failed transfer leaving the replacement WWN card unusable.
Feature: FOS-Infrastructure
Probability: Low
Found in Release: FOS7.0.0
Fabric OS v7.0.1 Release Notes v1.0
Technical Severity: High
Function: Other
Technical Severity: High
Function: 16G QSFP
Technical Severity: High
Function: Ports Admin
Technical Severity: High
Function: PORT FENCING
Technical Severity: High
Function: Other
Service Request ID: 673189
Page 41 of 67