Install Range Hood; Connect Vent System - Whirlpool UXW7230BS0 Use & Care Manual

30" wall-mount canopy range hood
Table of Contents

Advertisement

Available languages

Available languages

1.
00_
Using 2 or more people, hang range hood on 2 mounting
screws through the mounting slots on back of hood.
A
For non-vented (recirculating) installations only:
1. Assemble the air deflector with the duct cover bracket with
2 - assembly screws provided with the Recirculation
Kit.
C
A. Mounting screws
B. Mounting slots
C. Lower mounting screws
2. Remove the grease filter. See "Range Hood Care" section.
3. Level the range hood and tighten upper mounting screws.
4. Install 2 - 5 x 45 mm lower mounting screws and tighten.
1. Install transition on top of hood (if removed for shipping) with
2 - 3.5 x 9.5 mm sheet metal screws.
A. Vent transition
B. 3.5 x 9.5 mm screw
For vented installations only:
1. Fit vent system over transition piece.
2. Seal connection with clamps.
3. Check that back draft dampers work properly.
2.
A. Vent cover bracket
B. 2.9 x 6.5 mm screws
C. Deflector
Measure from the bottom of the air deflector to the bottom of
the hood outlet.
--A
S
...............
A. Air deflector
B. Vent clamp
C. X = length to cut vent duct
D. Vent duct
E. Exhaust outlet
3. Cut the duct to the measured size (X).
4. Remove the air deflector.
5. Slide the duct onto the bottom of the air deflector.
6. Place the assembled air deflector and duct over the exhaust
outlet from the hood.
7. Reassemble the air deflector to the duct cover bracket with
2 assembly screws.
8. Seal connections
with vent clamps.

Advertisement

Table of Contents
loading

Table of Contents