Download Print this page

Troy-Bilt 30248 Owner's Manual page 4

Hide thumbs Also See for 30248:

Advertisement

Available languages

Available languages

Section 1: Safety Rules
WARNING
WHEN
ADJUSTING
OR
MAKING
REPAiRSTOYOUR
GENERATOR
Disconnect
the spark piug wh_e from the spark plug and place
the vvh_ewhere it cannot contact
spark plug.
WNENTESTmNG
FOR ENGmNE
SPARK
Use approved spark plug tester:
DO NOT check for spark with spark plug removed,
WARNING
DO NOT touch hot surfaces and avoid hot exhaust gases.
Allow equipment
to cool before touching.
The generator
must be at least 5 feet from structures
having
combustible
wails and/or other combustible
materials.
Keep at least 3 feet of clearance on all sides of generator
for
adequate cooling, maintenance
and servicing_
Reflective exhaust heat may damage fuel tank causing fire.
Code of Federal Regulation
(CFR) Tide 36 Parks, Forests, and
Public Property
require equipment
pow,ered by an internal
combustion
engine to have a spark arrester, maintained
in
effective working
order, complying
to USDA Forest service
standard 5100-IC
or later revisiom In the State of California
a
spark attester
is required
under section 4442 of the California
Public resources
code. Other
states may have similar Iaws.
CAUTION
DO NC)T tamper with governed
speed_ Generator
supplies
correct
rated frequency
and voltage when running at governed
speed.
DO NOT modify generator
in any way:
See "Don't Overload
Generator".
Start generator
and let engine stabilize before connecting
electrical
loads,
Connect
electrical
loads in OFF position,
then turn ON for
operation,
]:urn electrical
loads OFF and disconnect
from generator
before
stopping
generator,
Use generator
only for intended
uses,
[f you have questions about intended use, ask dealer or call
1-888-61 1-6708,
Operate
generator
only on level surfaces.
DO NOT expose generator
to excessive moisture, dust, dirt,
or corrosive
vapors.
DO NOT insert any objects through cooling slots.
If connected
devices overheat, turn them off and disconnect
them from generator:
Shut off generator
if:
-electrical
output
is lost;
-equipment
sparks,
smokes,
or emits flames;
-unit vibrates
excessively.

Advertisement

loading