Storage
Data tag information is very important
if you need help from
our Customer Service Department or an authorized service
dealer.
The data tag (Figure 9) is located on the engine support on
the muffler side of the generator. For future reference, please
copy the model, revision, and serial number of the generator
in the space below.
m ln'a m
MODEL
REV NO
SERIAL
-_
AC VOLTS
]
ACAMPS
]
AC W!ATTS
]
DC VOLTS
]
DCAMPS
[
]
Single Phase / 60 Hz / 3600 RPM
Rated at 40 "C / Class F Insulation
Troy_Bilt@ is a registered trademark of
MTD and is used under license to
Bdggs
& Stratton
Power
Products
Group,
LLC
Jefferson,
Wl
888-611-6708
Copy Revision
Here
Copy Serial
Number Here
The generator
should
be started
at least once every
seven
days and allowed
to run at Heast 30 minutes.
If this cannot
be done
and you must
store
the unit
for more
than
30 days, use the following
guidelines
to prepare
it for
storage.
Generator
Storage
o Clean the generator
as outlined in "Generator
Cleaning".
o Check that cooling air slots and openings on generator
are open and unobstructed.
WANNING
DO NOT place a storage cover over a hot generator,
Let equipment cool for"a sufficient time before placing the
cover on the equipment.
Engine
Storage
See engine owner's manual for instructions.
Other
Storage
Tips
o To prevent gum from forming in fuel system or on
essential carburetor
parts, add fuel stabilizer into fuel
tank and fill with fresh fuel. Run the unit for several
minutes to circulate the additive through the carburetor.
The unit and fuel can then be stored for up to
24 months. Fuel stabilizer can be purchased locally.
o DO NOT store fuel from one season to another unHess
it has been treated
as described
above.
o Replace fuel container
if it starts
to rust. Rust and/or
dirt
in fuel can cause problems if it's used with this unit.
o Store unit in a clean and dry area.

Advertisement