LG LRTGC1815BK Service Manual page 13

Table of Contents

Advertisement

• General Control of Refrigerating
Cycle
NO,
ITEMS
UNIT
1
Pipe and
Min,
piping system
opening time
Welding
Nitrogen
pressure
N2 sealed
Confirm
parts
Nz leak
P, efiigeEvacuate
rati0n _me
STANDARDS
Pipe: within 1 hour.
Comp: within 10 minutes.
Drier: within 20 minutes.
Weld under Nitrogen
atmosphere.
(N2 pressure:
0.1 ~0.2 kg/cm =)
Confirm air leaking sounds
when removing robber cap.
Sound: usable
No sound: not usable
Min.
More than 40 minutes
PURPOSES
To protect
moisture
penetration,
To protect oxide
scale formation.
To protect
moisture
penetration.
To remove moisture,
REMARKS
The opening time should be reduced
to a half of the standards dudng rain
and rainy seasons (the penetration of
water into the pipe is dangerous).
- Refer to repair note in each part.
- R-t34a
refrigerant is more
susceptible
to leaks than R-12 and
requires more care during welding,
- DOnot apply f_'ca to pipas before and
after welding to protect pipefrom cracking.
- In case of evaporator
parts, if it
doesn't make sound when removing
rubber cap, blow dry air or N= gas for
more than I rain and use the parts.
Cycle ,.................t .................. _ ...............................................................
÷.................................... _ ................................................................................
Vacuum
Ton"
Below 0.03 (ref)
Note: Onlu applicable to the model
degree
equipped with reverse flow
protect piate.
................
i. ..................
_...............................................................
+ ....................................
b................................................................................
Vacuum
EA
High end low pressure sides
Vacuum efficiency can be improved
are evacuated at the same
by operating compressor during
time for models above 200 L
evacuation.
Vacu_n
EA
Use R-134a exclusive
To protect mixing
The rubber pipes for R-12 refrigerant
piping
manifold,
of mineral end
shall be melted when they ere used for
ester oils.
R-134a refrigerant (causes of leak),
................
1...................
1...............................................................
÷ ....................................
_................................................................................
Pipe
EA
Use R-134a exclusive.
To protect R-12
coupler
refrigerant mixing.
................
1...................
1...............................................................
÷ ....................................
_................................................................................
Outlet
R-134a exclusive.
(Socket)
Plug
R-134a exclusive.
Refrigerant
EA
weighing
Drier
replacement
Leak check
Use R-134a exolusiveiy.
Weighing allowance: +5g
Note: Winter: -5g
Summer: +5g
- Use R-134a exclusively for
R-134e refrigerator.
* Use R-12 exclusively for
R-12 refrigerator.
- Replace_er whenever repairing
reftigerater
cyole p ipiog.
- Do not use soapy water for
check. It may be sucked
into the pipe by vacuum.
Do not mix with
R-12 refdgerent.
To remove the
moisture from
pipe inside.
Defect
refrigerant leak
area.
- Do not weigh the refrigerant at too
hot or too cold an area.
(77°F[25°C]
is adequate,)
- Make Copper bombe
Socket: 2SV
Plug: 2PV R-134a
Note: Do not burn O-dog (rubber)
during welding.
- Check oil leak at refrigerant leek
area. Use electronic leak detector if
oil leak is not found.
The electronic
leak detector is very
sensitive to halogen gas in the air. It
also can detect R-141b in urethane.
Please practice, therefore, many
times before use.