Room Air Conditioner Voltage Limits - LG LP090HSD-Y8 Owner's Manual

Packaged terminal air conditioner/heat pump
Table of Contents

Advertisement

Maintenance
and Service
Compressor
cycles
on
overload.
Insufficient
cooling
or heating
Excessive
noise.
Check
the voltage.
See the limits on the preceding
page. If not within limits,
call an electrician.
Check
overload,
if externally
mounted.
Replace
if open. (If the compressor
temperature
is
high, remove
the overload,
cool, and retest.)
If not running,
determine
the cause.
Replace
if
required.
. Remove
the cabinet,
inspect
the interior
surface
of the
condenser;
if restricted,
clean carefully
with a vacuum
cleaner
(do not damage
fins) or brush. Clean
the
interior
base before
reassembling.
. If condenser
fins are closed
over a large area on the
coil surface,
head pressures
will increase,
causing
the
compressor
to cycle. Straighten
the fins or replace
the
coil.
Test capacitor.
Check
the terminals.
If loose,
repair or replace.
Check
the system
for a restriction.
If restricted,
clean or replace.
Close
if open.
Determine
if the unit is properly
sized for the area to
be cooled.
Check
the set screw or clamp.
If loose or missing,
correct.
If the blower or fan is hitting air guide,
rearrange
the air handling
parts.
Carefully
rearrange
tubing not to contact,
compressor,
shroud,
and barrier.
@
ROOM AIR CONDITIONER VOLTAGE LIMITS
NAME
PLATE
RATING
MINIMUM
MAXIMUM
208/230
V
187 V
253 V
Owner's Manual
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lp120csd-y8Lp090csd-y8Lp120hsd-y8