LG LP090HSD-Y8 Owner's Manual page 15

Packaged terminal air conditioner/heat pump
Table of Contents

Advertisement

Control Locations
FUNCTION:
If the unit has a malfunction, a green OPERATIONLED
located on the Display PCB used by the unit to
indicate the errors.
USE:
If the customer has to register a complaint to the service center, he can be very clear about registering
the complaint that what is happening & by referring the user's manual the customer can clearly define
the problem.
So that the engineer should go fully prepared with the prescribled tools to be used regarding that
problem. It also keeps the customer aware about the unit.
Here are some of the problems defined below for which the LED indicates by flashing number of times
the error has been reconrded against it.
The errors are the mentioned which is as follows:
• Electrical
Controls
ON
Normal
OFF
No power / failed board
Fault Codes
CH 01
Indoor Air Thermistor
Error
CH 02
Indoor Coil Thermistor
Error
CH 03
Outdoor Air Thermistor
Error (PTHP Only)
CH 04
Outdoor Coil Thermistor
Error (PTHP Only)
CH 05
Mode Error
CH 06
Setpoint Error
CH 07
Bad Thermistor Wiring
• Manual Controls
ON
Normal
OFF
No power / failed board
Fault Codes
1
Indoor Air Thermistor
Error
2
Indoor Coil Thermistor
Error
3
Outdoor Air Thermistor
Error (PTHP Only)
4
Outdoor Coil Thermistor
Error (PTHP Only)
5
Mode Error
6
Setpoint Error
7
Bad Thermistor Wiring
LED Flash Rate
0.25 sec On per flash, 0.25 sec OFF between flashes,
2.00 sec OFF between codes.
@