LG LP090HSD-Y8 Owner's Manual page 24

Packaged terminal air conditioner/heat pump
Table of Contents

Advertisement

Maintenance
and Service
Fan motor
noise.
Compressor
will
not run, but fan
motor
runs.
Check
grommets;
if worn or missing,
replace
them.
If cracked,
out of balance,
or partially
missing,
replace
it.
Tighten
it.
• If knocking
sounds
continue
when running
or loose,
replace
the motor. If the motor hums or noise appears
to be internal
while
running,
replace
motor.
Check
voltage. See the limits on the preceding,
page.
If not within
limits, call an electrician.
Check
the wire connections,
if loose, repair or
replace
the terminal.
If wires are off, refer to wiring
diagram
for identification,
and replace.
Check wire
locations.
If not per wiring
diagram,
correct.
Check
for continuity,
refer to the wiring
diagram
for
terminal
identification.
Replace
the switch
if circuit
is
open.
Check
the position
of knob If not at the coldest
setting,
advance
the knob to this setting
and restart
unit.
Check
continuity
of the thermostat.
Replace
thermostat
if circuit
is open.
Check
the capacitor.
Replace
if not within +10%
of manufacturer's
rating.
Replace
if shorted,
open, or damaged.
Check
the compressor
for open circuit
or ground.
If
open or grounded,
replace
the compressor.
Check
the compressor
overload,
if externally
mounted.
Replace
if open. (If the compressor
temperature
is high, remove
the overload,
cool it,
and retest.)
24
Room Air Conditioner

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lp120csd-y8Lp090csd-y8Lp120hsd-y8

Table of Contents