Nordyne 16 SEER User's Manual & Installation Instructions page 17

16 seer two stage r-410a split system
Hide thumbs Also See for 16 SEER:
Table of Contents

Advertisement

TROUBLESHOOTING
- CONTINUED
IVliswired IVlodule indication
Green
LED is not on, module
does not power up
Green
LED
intermittent,
module
powers
up only when
compressor
runs
Trip LED is on, but system and
compressor
check OK
TRIP
LED
and ALERT
LED
flashing together
ALERT Flash CODE 3 displayed
incorrectly
(Compressor
short
cycling)
ALERT Flash Code 5, 6, or 7
displayed
incorrectly
(Open
Circuit,
Open Start
Circuit
or
Open Run Circuit)
ALERT
Flash Code
6 (Open
Start
Circuit)
displayed
for
Code 7 (Open Run Circuit) or
vice-versa
ALERT Flash Code 8 displayed
incorrectly (Welded Contactor)
Recommended
Troubleshooting
Action
. Determine if both R & C module terminals are connected.
. Verify voltage is present at module's R & C terminals.
. Determine
if R & Y terminals
are wired in reverse.
. Verify modules R and C terminals have a constant source.
. Verify Y terminal is connected to 24VAC at contactor coil.
. Verify voltage at contactor coil falls below 0.5VAC when
off.
. Verify 24VAC is present across Y & C when thermostat
demand signal is present. If not, R & C are reversed wired.
. Verify R and C terminals are supplied with 19 - 28VAC.
. Verify Y terminal is connected to 24VAC at contactor coil.
. Verify voltage at contactor coil falls below 0.5VAC when
off.
,, Verify the compressor
run and start wires are routed
through the module's current sensing holes.
. Verify the Y terminal is connected to 24VAC at contactor
coil.
. Verify voltage at contactor coil falls below 0.5VAC when
off.
,, Verify the compressor
run and start wires are routed
through the correct module sensing holes.
. Determine
if module's Y terminal is connected.
. Verify Y terminal is connected to 24VAC at contactor coil.
. Verify 24VAC is present across Y & C when thermostat
demand signal is present. If not, R and C are reversed
wired.
. Verify voltage at contactor coil falls below 0.5VAC when
off.
. Review Thermostat
Demand Wiring (page 10) for Y & C
wiring.
Table 5. Module Wiring Troubleshooting
17